NEC Univerge SV8100 Programming Manual page 748

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Item
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
2 - 712
Name
Receive Hook Flash Duration
Min. Time (E&M)
Receive Hook Flash Duration
Max. Time (E&M)
Receive Hook Flash Duration
Min. Time (OPX)
Receive Hook Flash Duration
Max. Time (OPX)
Loop Off Guard Time (Loop)
Loop Off Guard Time (Ground)
Loop Off Guard Time (DID)
Loop Off Guard Time (E&M)
Loop Off Guard Time (OPX)
Double Ringing Send Time 1
(OPX)
Double Between Ringing Send
Time 1 (OPX)
Double Ringing Send Time 2
(OPX)
Double Between Ringing Send
Time 2 (OPX)
Single Ringing Send Time (OPX)
Receive DP Make Max. Time
(ALL)
Receive DP Break Min. Time
(ALL)
Receive DP Break Max. Time
ALL)
Single Between Ringing Send
Time (OPX)
Guard Time 1 (Loop)
Input Data
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Default
3
300ms
6
600ms
3
300ms
6
600ms
20
2000ms
20
2000ms
20
2000ms
20
2000ms
20
2000ms
5
500ms
5
500ms
25
2500ms
30
3000ms
10
1000ms
9
900ms
9
900ms
9
900ms
9
900ms
9
900ms

Hide quick links: