81-13: E1 Trunk Timer Setup (Ot) - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-13: E1 Trunk Timer Setup to define the basic timer setting of E1
Trunk.
Item
01
02
03
04
16
17
18
19
20
21
22
23
Programming Manual
Trunk Port Number
Name
Loop Current Detection Time
(Loop)
Clear Signal (Open Loop)
Detection Time
Transmit Clear Signal Time for
Forced Release
Receive DP Inter-digit min. Time
Pause Time
Pulse Dial Break Time
Pulse Dial Make Time
Pulse Dial Inter-digit Time
Receive DP Make min. Time
Receive DP Make max Time
Receive DP Break min. Time
Receive DP Break max Time

81-13: E1 Trunk Timer Setup (OT)

Input Data
1~255
(16ms ~ 4080ms)
1~255
(16ms ~ 4080ms)
1~255
(16ms ~ 4080ms)
1~255
(4ms ~ 1020ms)
1~255
(64ms ~ 16320ms)
1~255
(4ms ~ 1020ms)
1~255
(4ms ~ 1020ms)
1~255
(16ms ~ 4080ms)
1~255
(4ms ~ 1020ms)
1~255
(4ms ~ 1020ms)
1~255
(4ms ~ 1020ms)
1~255
(4ms ~ 1020ms)
Issue 10.1
1~200
Default
3
48ms
50
800ms
50
800ms
125
500sec
47
3008ms
15
60ms
10
5000ms
50
800ms
3
12ms
19
76ms
5
20ms
26
104ms
2 - 723