22-02: Incoming Call Trunk Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Level:
IN
Description
Use Program 22-02: Incoming Call Trunk Setup to assign the incoming trunk type
for each trunk. There is one item for each Night Service Mode.
Input Data
Item
No.
01
Programming Manual
Program 22 : Incoming Call Setup
Trunk Port Number
Day/Night Mode
Item
0
= Normal
Incoming
Type
1
= VRS (second
2
= DISA
3
= DID
4
= DIL
5
= E&M Tie line
6
= Delayed VRS
7
= ANI/DNIS
8
= DID(DDI) Mode
Conditions
When connecting to T1 trunks, after changing Program 22-02-01 to match the
Telco connected T1 service type, the T1 cable or the T1 blade must be unplugged
and then reconnected for the T1 blade to sync.
When the trunk type is set to 3 (DID), the DID Transfer to Destination in 22-11-04
for each DID feature is not supported. This feature is supported only for DID
trunks when assigned as VRS.
When the trunk type is set to 3 (DID), the DID Intercept Destination feature for
each DID is not supported. This feature is supported only for DID trunks assigned
as VRS.

22-02: Incoming Call Trunk Setup

Input Data
Default
0
dial tone if no
VRS installed)
Switching
001~200
1~8
Description
Use this option to set the
feature type for the trunk
you are programming.
Issue 10.1
Related
Program
14-04
2 - 343

Hide quick links:

Advertisement

Table of Contents
loading