NEC Univerge SV8100 Programming Manual page 905

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Alarm
Type
Report
No.
3
0
Connection
2
fault between
CD-CP00 and
other PKGs.
4
0
PKG S/W
2
Download
Error
5
0
Cooling fan
1
error
Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The error occurred when
communicating with the
package. When the
package is broken, it
recognizes it as a
communication fault.
The unit program could not
be downloaded normally.
The unit could not able to
be started normally.
The cooling fan does not
work normally.
Cause
Action
1.The unit is not
1.Please insert the unit
completely
firmly.
inserted.
2.The power-supply
2.The power-
voltage must use
supply voltage of
another power supply
the system is
when is in the range of
outside ratings.
ratings or measuring
3.The equipment
with the voltmeter, and
that generates the
deviating from the rated
noise in the same
range.
power supply
3.Please use the power
system as the
supply besides the
power supply origin
equipment with the
of the system is
possibility of the noise
connected, and it
source.
malfunctions
4.Please separate as
because of the
much as possible and
power supply
use a main device from
noise.
the equipment by which
4.The equipment to
you seem may
which it is adjacent
generate the radiation
to of a main device,
noise.
and has put out the
5.Please ground the
radiation noise
chassis correctly.
exists, and it
malfunctions
because of the
radiation noise.
5.The chassis is
not properly
grounded.
1.The package
1.Delete slot
software is not
information that
stored in the
corresponds by
downloaded USB
PRG90-05-01 to delete
memory.
package information
2.The stored
that was installed
package software
before.
is illegal.
2.There is a possibility
Package
that the unit program is
information that
broken though an
was installed
external factor of the
before remains.
noise etc. is thought.
3.Please load into the
USB memory and try
again when you back
up the unit program.
4.PleaseCheck with
maker on uncertain
points.
1.The cooling fan
1.Confirm the cooling
has stopped
fan is turning.
working.
2.Verify the cooling fan
2.The cooling fan
mounting.
has come off.
Issue 10.1
Alarm
Recovery
Status
When unit is
ERR
confirmed, the
REC
error is
recovered.
Please
ERR
exchange
REC
units, though
it is likely to
restore by
mounting the
unit again.
When the unit
program is
normally
downloaded,
the error is
recovered.
Replace the
cooling fan if it
is defective.
2 - 869

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents