NEC Univerge SV8100 Programming Manual page 280

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Input Data
Item
No.
04
05
06
07
Feature Cross Reference
2 - 244
Item
Dial Sending Start Time for SLT or ARS
When ARS or an analog extension user
accesses a trunk and dials an outside call, the
system waits this time before outdialing the
first digit.
When using a third-party external paging
device, set this option to 1. In addition, set
Program 20-03-03 to 1.
SLT Operation Mode
Headset Ringing Start Time (for SLT)
Define the headset ringing start time. After this
time expires from the time when a single line
telephone is off-hook, the system sets the
single line telephone to headset ringing mode.
Trunk Call Dial Forced Sending Start Time
(Forced Dial)
Conditions
None
Single Line Telephones
UNIVERGE SV8100
Input Data
Default
0~64800s
3 (OT)
1 (AU)
0
= Normal
Mode
1
= Extended
Mode 1
2
= Extended
Mode 2
0~64800s
0~64800s
Program 20 : System Option Setup
Related
Program
20-03-03
0
5
20-13-38
0
20-03-03
20-03-04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents