Program 12 : Night Mode Setup; 12-01: Night Mode Function Setup - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Level:
IN
Description
Use Program 12-01: Night Mode Function Setup to set up the Night Mode
options. Refer to the following chart for a description of each option, its range
and default setting.
Input Data
Item
No.
01
02
03
04
Conditions
None
Feature Cross Reference
Programming Manual

Program 12 : Night Mode Setup

12-01: Night Mode Function Setup

Item
Input Data
0 = Off
Manual Night
Mode Switching
1 = On
0 = Off
Automatic Night
Mode Switching
1 = On
0 = Not used
Night mode
switch operating
1 - 8 (Operation
mode
Mode1 - 8)
0 = Not used
General Purpose
Contact Detector
1 - 1 = Detector
Number
When 49-06 is set
this set will ignore
the 49-06 setting.
Even if the operation mode is changed manually, the operation mode changes according to the
schedule set up.
Night Service
Default
Description
1
Allow/Prevent as activating
Night Service by dialing a
service code.
1 (OT)
According to a preset
0 (AU)
schedule, enable or disable
Automatic Night Service for
the system.
0
Use this option to set the
operation mode of the CPU
Night Service mode switch
sensors (external Night
Mode Selector Switch). The
Night Service mode affects
trunk inbound and outbound
routing.
0
Set the detection circuit of
the general purpose relay of
the PGD Adapter when
switching night mode
(Program 10-41).
Program
12
Related
Program
11-10-01
12-02
12-03
12-04
10-41
2 - 127

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents