Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Level:
IN
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define the
various basic timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Input Data
Item
No.
Programming Manual
Layer 3 Timer Type Number
Item
01
T301
Specifies the timer value in 1/100ths
of a second of the timer to be started
when the ALERT message is
received.
02
T302
Specifies the timer value in 1/100ths
of a second of the timer to be started
when the SETUP ACK is sent. Timer
is also restarted when INFO is
received.
03
T303
Specifies the timer value in 1/100ths
of a second of the timer to be started
when SETUP is sent.
04
T304
Specifies the timer value in 1/100ths
of a second of the timer to be started
when the SETUP ACK is received.
Timer is also restarted when INFO is
received.
05
T305
Specifies the timer value in 1/100ths
of a second of the timer to be started
when DISC without progress No. 8 is
sent.
06
T306
Specifies the timer value in 1/100ths
of a second of the timer to be started
when DISC with progress indicator
No. 8 is sent. This timer is valid for
Network side use only.
07
T307
Specifies the timer value in 1/100ths
of a second of the timer to be started
when SUSPEND ACK is sent. This
timer is valid for Network side use
only.
Description
1~5
Input Data
0,180~254 (sec)
1~254 (sec)
1~254 (sec)
0~254 (sec).
1~254 (sec)
0~254 (sec)
1~254 (sec)
Issue 1.0
Default
180 (sec)
15 (sec)
4 (sec)
30 (sec)
30 (sec)
30 (sec)
180 (sec)
2 - 613