Issue 10.1
Input Data
Item
No.
Feature Cross Reference
2 - 284
11
Automatic Changing System Clock When Date/
Time Information Element Received
12
Call Forward Options (Auto Connect Send)
Incoming Calls Forwarded Out Automatically Return
Connect Message When Outgoing Call Receives
Alerting Message.
13
Local Busy Tone (Release)
Busy tone send when T-point receiving a RELEASE
message from Network.
14
No Response Release Send
Operation mode setting for when second T303 timer
expires.
15
Call Reference Selection for PRI 2B-Channel
Transfer
When transferring a call via 2B-Channel Transfer,
select Call Reference information as "Negative Integer"
(0), or as is "No Edit" (1).
Conditions
None
ISDN Compatibility
Item
UNIVERGE SV8100
Input Data
0
= Disable (Off)
1
= Enable (On)
0
= Normal – No
Message (Off)
1
= Normal – No
Message (On)
0
= Off
1
= On
0
= Off
1
= On
0 = Negative Integer
1 = No Edit
Program 20 : System Option Setup
Default
1 (OT)
0 (AU)
0
0 (OT)
1 (AU)
0