NEC Univerge SV8100 Programming Manual page 909

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Alarm
Type
Report
No.
40
0
CS error noti-
0
fication 2.
50
1
0
System Start
Notification
51
0
System Data
0
change
52
0
--- Not Used ---
0
54
0
License
2
Management
Table Full
55
0
Regular
2
maintenance
exchange
notification.
57
0
IP Collision
2
Error
58
0
Failure of
2
Outbound IP
Connection
Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
CS detected the factor that
the noise is generated
between CS-PS, BBIC
reset was executed, and it
was restored automatically.
The system started.
CD-CP00 Upgrade is
performed or Programming
change is made.
A new TCP/IP terminal and
the DSP board were not
able to be added to the
application license
management table.
• The license management
table is registering full.
The regular maintenance
exchange day has passed.
Collision(01) indicates the
address programmed in
10-12-01 has been
duplicated. Collision (02)
indicates the address
programmed in 10-12-09
has been duplicated.
Collision(03) ~
Collision(10) indicates the
addresses programmed in
84-26-01 have been
duplicated. (03) is GW1 ~
(10) is GW8.
01: Programming session
is already active.
02: Not setting of IP
Address or Port.
03: Caller ID does not
match.
10: Cannot get IP Address.
11: Socket Open Error.
12: Socket Port Setting
Error.
13: TCP Session Timeout.
Cause
Action
1. Outgoing noise.
Please confirm the
2. Method of setting
following matter when
up CS.
happening frequently
3. Wiring to
when operating it.
connect CSIU unit
1. Please confirm CS is
with CS.
normally connected.
4. Hard defect of
2. Please confirm the
CS.
wiring between
5. Hard defect of
CSIU-CS is normal.
CSIU.
3. Please exchange
CS.
4. Please exchange
CSIU.
The system was
No action needed.
started.
No action needed.
Maximum 512
Please delete license
license information
information on an
on the TCP/IP
unnecessary TCP/IP
terminal is
terminal with PRG
registered, and a
90-44.
new terminal
cannot be
registered.
• The regular
Please do the
maintenance
maintenance
exchange day that
exchanges of pertinent
had been set with
parts, and set the next
PRG 90-51
regular maintenance
exceeded it.
exchange day with
PRG 90-51.
An IP address
Confirm that the
programmed in
addresses assigned in
either 10-12-01, 10-
10-12-01, 10-12-09,
12-09 or 84-26 is
and 86-26 are not
duplicated
duplicated anywhere
somewhere on the
else on the network.
same segment of
the network. The
system will check
every 5 minutes
and is not a
programmable
increment.
Issue 10.1
Alarm
Recovery
Status
This error has
ERR
been
REC
recovered
when it is
notified.
WAR
The excess
ERR
REC
on the regular
maintenance
exchange day
is canceled by
changing
PRG 90-51 or
when the
function is
invalidated,
the error is
recovered.
2 - 873

Hide quick links:

Advertisement

Table of Contents
loading