90-10: System Alarm Setup; Table 2-20 Description Of Alarm - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 10.1
Level:
IN
Description
Use Program 90-10: System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm information is reported to the pre-defined destination.
Input Data
Item No.
Alarm
Type
Report
No.
1
0
PKG Initialize
2
Error.
2
0
PKG Mount-
2
ing Error
2 - 868
Program 90 : Maintenance Program
Alarm Number
Item
01
Alarm Type
02
Report

Table 2-20 Description of Alarm

Name
Content of Alarm
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.

90-10: System Alarm Setup

Input Data
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
1 = Report (autodial)
Cause
Action
1. PKG not inserted
1. Insert PKG firmly.
firmly.
2. Insert PKG firmly.
2. PKG was
3. Delete slot
removed, but not
information in
reinserted firmly.
PRG 90-05 and insert
3. Old PKG data
the PKG again.
still reported due to
no initialization.
1.The package is
1.Please insert the
not completely
package firmly.
inserted.
2.Please try again after
2.The package is
initializing the system
out of order.
data once when LED
doesn't blink normally.
3.Exchange packages.
Program 90 : Maintenance Program
UNIVERGE SV8100
001~100
Alarm
Recovery
Status
During
ERR
initialization,
REC
the PKG is
recognized.
When unit is
ERR
reconfirmed,
REC
the error is
recovered.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents