Description
Use Program 22-09: DID Basic Data Setup to define the basic setting of Dial-In
incoming calls for each trunk group.
Input Data
Item
No.
01
02
03
04
05
06
07
2 - 352
Program 22 : Incoming Call Setup
Trunk Group Number
Item
Expected Number of Digits
Enter the number of digits the table
expects to receive from the telco. Use this
program to make the system compatible
with 3- and 4-digit DID service.
If ISDN trunks, we analyze the last digits
that are set here. If it is T-1 or analog DID,
it analyzes the first digits that are assigned
here.
Received Vacant Number Operation
Use this option to enable or disable
Vacant Number Intercept.
Sub-Addressing Mode
DID Receiving Mode for ISDN
Local Code Digits
(Only Overlap Receiving Mode)
Local Code
(Only Overlap Receiving Mode)
Pilot Code
(Only Overlap Receiving Mode)

22-09: DID Basic Data Setup

001~100
Input Data
1~8
0
= Disconnect (Cut)
1
= Transfer (Refer to
Program 22-12: DID
Intercept Ring Group on
page
2-361.)
0
= Extension # Specify
(Intercom)
1
= DID Conversion Table
0
= Enbloc Receiving
1
= Overlap Receiving
0~15 (0 = No Local Code)
Dial (maximum 16 digits)
Dial (1 digit: 0~9)
Program 22 : Incoming Call Setup
UNIVERGE SV8100
Default
4 (OT)
2 (AU)
0
0
0
0
No Setting
No Setting