4.3 The Drive and Programming Modes
u

Verifying Parameter Changes: Verify Menu

The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. The Verify Menu helps determine which settings
have been changed, and is particularly useful when replacing a drive. If no settings have been changed and all parameters remain at the original default
settings, then the Verify Menu will read
Note: The Verify Menu will not display parameters from the A1 group (except for A1-02) even if those parameters have been changed from default settings.
The following example is continued from page 63. Here, parameter C1-01 is accessed using the Verify Menu and is changed again to 20.0 s.
To check the list of edited parameters:
1.
Turn on the power to the drive. The initial display appears.
2.
Press
until the display reads, "Verify."
Press
to enter the list of parameters that have been edited from their original default settings.
3.
Scroll through the list by pressing the
4.
Press the
key until C1-01 appears.
5.
Press the
key to access the setting value. (number farthest to the left flashes)
u

Switching Between LOCAL and REMOTE

Entering the run command using the LED operator is referred to as LOCAL, while entering the run command from an external device via the control
circuit terminals or network option card is referred to as Remote.
WARNING! Sudden Movement Hazard. The drive may start unexpectedly if the Run command is already applied when switching from LOCAL mode to REMOTE mode when
b1-07 = 1, resulting in death or serious injury. Be sure all personnel are clear of rotating machinery and electrical connections prior to switching between LOCAL mode and REMOTE
mode.
There are three ways to switch between LOCAL and REMOTE.
Note: 1. After selecting LOCAL, LO/RE will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
Using the LO/RE Key on the LED Operator
n
1.
Turn on the power to the drive. The initial display appears.
Press
. LO/RE will light up. The drive is now in Local.
2.
To set the drive for REMOTE operation, press the
Using Input Terminals S1 through S7 to Switch between LO/RE
n
Switch between LOCAL and REMOTE using one of the digital input terminals S1 through S7 (set the corresponding parameter H1-01 through H1-07 to
"1").
Follow the example below to set the digital input terminals.
Note: 1. For a list of digital input selections,
2. Setting a multi-function input terminal to a value of 1 disables the LO/RE key on the LED operator.

Parameters Available in the Setup Group

u
Setup Mode (StUP)
n
Parameters used for this drive are classified into A to U. To simplify the drive setup, frequently used parameters are selected and input into Setup Mode.
1.
To set a parameter, the Setup Mode must be displayed first.
2.
If the parameter setting is insufficient, set the parameters in the Parameter Setting Mode.
Note: When parameter A1-02 (Control Method Selection) is changed, some parameter set values are also changed automatically. Execute the A1-02 setting before Auto-tuning.
64
. The Verify menu also allows users to access and re-edit edited parameters.
Step
key.
Step
key again.
Refer to Parameter List on page
293.