4.3 The Drive, Programming, and Clock Adjustment Modes
u

Verifying Parameter Changes: Verify Menu

The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. The Verify Menu helps
determine which settings have been changed, and is particularly useful when replacing a drive. If no settings have been changed,
the Verify Menu will read "None". The Verify Menu also allows users to quickly access and re-edit any parameter settings
that have been changed.
Note:
The Verify Menu will not display parameters from the A1 group (except for A1-02) or E5-01 even if those parameters have been changed
from their default settings.
The following example is a continuation of the steps above. Here, parameter C1-02 is accessed using the Verify Menu, and
is changed again from 10.0 s to 20.0 s.
To check the list of edited parameters:
1.
Turn on the power to the drive. The initial display appears.
2.
Press
or
until the display shows the top of the Verify Menu.
Press
to enter the list of parameters that have been edited from their original default
settings.
3.
If parameters other than C1-02 have been changed, use
appears.
4.
Press
to access the setting value. Left digit flashes.
120
Step
or
to scroll until C1-02
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Display/Result
- MODE -
DRV
Rdy
FREF (OPR)
U1-01= 0.00Hz
U1-02= 0.00Hz
LSEQ
U1-03= 0.00A
LREF
JOG
FWD
FWD/REV
- MODE -
PRG
Modified Consts
Modified
X Parameters
HELP
FWD
DATA
- VERIFY - PRG
Rdy
Accel Time 1
C1-02
= 20.0sec
(0.0~6000.0)
"10.0sec"
Home
FWD
DATA
- VERIFY - PRG
Rdy
Accel Time 1
C1-01=0020.0sec
(0.0~6000.0)
"10.0sec"
Home
FWD
DATA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents