YASKAWA V1000 Series Technical Manual page 145

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
d7-01
d7-02
d7-03
Setting
44
45
46
Multi-Function Inputs H1-01 to H1-07
Detailed Description
The figure below illustrates how multi-function input terminal settings operate.
When two signals from d7-01 through d7-03 differ in sign, the +/- Speed function can be used.
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Parameter Name
Offset Frequency 1
Offset Frequency 2
Offset Frequency 3
Function Name
Offset Frequency 1 Calculations
Offset Frequency 2 Calculations
Offset Frequency 3 Calculations
Frequency
Reference
Offset Frequency 1 [d7-01]
Multi-Function Input (44) = on
(Signed)
Offset Frequency 2 [d7-02]
Multi-Function Input (45) = on
(Signed)
Offset Frequency 3 [d7-03]
Multi-Function Input (46) = on
(Signed)
Figure 5.33 Offset Frequency Operation
Frequency Reference
Offset Frequency [d7-01]
Multi-Function Input (44) = On
(Positive Value)
Offset Frequency [d7-02]
Multi-Function Input (45) = On
(Negative Value)
Figure 5.34 Offset Frequency and ± Speed Timing
5.4 d: Reference Settings
Setting Range
-100.0 to 100.0
-100.0 to 100.0
-100.0 to 100.0
+
SFS
+
+
+
+
+
+
SFS
+
+
+
Default
0%
0%
0%