YASKAWA V1000 Series Technical Manual page 105

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
o2-04
*Although the control method set to A1-02 is unaffected when performing a 2-wire or 3-wire initialization, the drive will automatically change A1-02
according to the value set to parameter A1-06.
Related Parameters
No.
Parameter Name
A1-01
Access Level Selection
A1-03
Initialize Parameter
A2-01 to A2-32
Preferred Parameters 1 to 32
o2-03
User Parameter Default Value
Application Presets
Below is a list of Application Presets and the settings automatically assigned to the parameters.
1: Water Supply Pump Application: Parameters and Settings
No.
A1-02
Control Method Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Rating
E1-03
V/f Pattern Selection
E1-07
Mid Output Frequency (FB)
E1-08
Mid Output Frequency Voltage (VC)
L2-01
Momentary Power Loss Operation Selection
L3-04
Stall Prevention Selection during Deceleration
Parameters below are automatically saved as Preferred Parameters (A2-01 to A2-16):
No.
b1-01
Frequency Reference Selection
b1-02
Run Command Selection
b1-04
Reverse Operation Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
E1-03
V/f Pattern Selection
E1-07
Mid Output Frequency (FB)
2: Conveyor Application Parameters and Settings
No.
A1-02
Control Method Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Rating
L3-04
Stall Prevention Selection during Deceleration
Parameters below are automatically saved as Preferred Parameters (A2-01 to A2-16):
No.
A1-02
Control Method Selection
b1-01
Frequency Reference Selection
b1-02
Run Command Selection
C1-01
Acceleration Time 1
3: Exhaust Fan Application: Parameters and Settings
No.
A1-02
Control Method Selection
b1-04
Reverse Operation Selection
C6-01
Duty Selection
E1-03
V/f Pattern Selection
E1-07
Mid Output Frequency (FB)
E1-08
Mid Output Frequency Voltage (VC)
L2-01
Momentary Power Loss Operation Selection
L3-04
Stall Prevention Selection during Deceleration
Parameters below are automatically saved as Preferred Parameters (A2-01 to A2-16):
No.
b1-01
Frequency Reference Selection
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
0: Operation only
1: Preferred Parameters (access to a set of parameters selected by the user)
2: Advanced Access Level (A) and Setup Access Level (S)
0: No Initialize
1110: User Initialize
2220: 2-Wire Initialization
3330: 3-Wire Initialization
5550: oPE04 Reset
b1-01 to 02-08
Allows storing of parameter settings as a User Initialization Selection.
0: No Change
1: Set Defaults - Saves current parameter settings as user initialization.
2: Clear All - Clears the currently saved user initialization.
Name
Parameter Name
Parameter Name
Parameter Name
Parameter Name
Parameter Name
Parameter Name
Drive/kVA Selection
Setting Range
0: Open Loop Vector
1: Reverse prohibited
1.0 s
1.0 s
1: Normal Duty
0FH
30.0
50.0
1: Enabled
1: Enabled
No.
E1-08
Mid Output Frequency Voltage (VC)
E2-01
Motor Rated Current
H1-05
Multi-Function Digital Input Terminal S5 Function Selection
H1-06
Multi-Function Digital Input Terminal S6 Function Selection
H1-07
Multi-Function Digital Input Terminal S7 Function Selection
L5-01
Number of Auto Restart Attempts
0: Open Loop Vector
3.0 s
3.0 s
0: Heavy Duty
1: Enabled
No.
C1-02
Deceleration Time 1
E2-01
Motor Rated Current
L3-04
Stall Prevention Selection during Deceleration
0: Open Loop Vector
1: Reverse Prohibited
1: Normal Duty
0FH
30.0
50.0
1: Enabled
1: Enabled
No.
E1-07
Mid Output Frequency (FB)
5.1 A: Initialization
Default
2
0
Determined by A1-06
0
Optimum Setting
Parameter Name
Optimum Setting
Parameter Name
Optimum Setting
Parameter Name
Page
-
-
-
-
5
105