YASKAWA V1000 Series Technical Manual page 73

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
Parameter Name
b6-02
Dwell Time at Start
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
Note: Read the instructions listed in
No.
Parameter Name
A1-02
Control Mode
b1-01
Frequency Reference Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-01
Duty Cycle
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
d1-03
Frequency Reference 3
H1-05
Multi-Function Digital Input Terminal S5 Function
H1-06
Multi-Function Digital Input Terminal S6 Function
H2-02
Terminals P1 Function Selection (open-collector)
L3-04
Stall Prevention Selection during Decel
L8-05
Input Phase Loss Protection Selection
L8-07
Output Phase Loss Protection
L8-38
Carrier Frequency Reduction
L8-41
Current Alarm Selection
No.
Parameter Name
b1-01
Frequency Reference Selection
C1-01
Acceleration Time 1
C1-02
Deceleration Time 1
C6-02
Carrier Frequency Selection
d1-01
Frequency Reference 1
d1-02
Frequency Reference 2
Note: A sequence to release the brake is needed when the multi-function output photocoupler P2-PC closes.
information.
Hoist Application Preset Specifics
n
This section lists some important points when using the Hoist Application Preset (A1-06 = 6).
Conditions for Opening and Closing the Holding Brake
Use an output signal as described below to operate the holding brake in a hoist application.
Make sure that frequency detection is set so that it does not operate during baseblock (L4-07 = "0"). Even when an external baseblock command is present,
the output frequency will rise when a run command is entered. If frequency detection were to be enabled during baseblock, (i.e., L4-07 = 1) then the brake
would be improperly released. To activate and release the brake using the multi-function output terminals P2-PC, program the drive as shown in the table
below:
Brake Open/Close
Function
Parameter
L4-07 = 0
Frequency Detection 2
H2-03 = 5
<1> This setting range is available when using OLV Control. In V/f Control, set the level as the motor rated slip frequency pulse 0.5 Hz. Not enough motor torque will be created if this value is
set too low, and the load may tend to slip. Make sure this value greater than the minimum output frequency and greater than the value of L4-02 as shown in the diagram below. If this value
is set too high, there may be a jolt at start.
<2> Adjust Hysteresis for Frequency Detection 2 by changing the frequency detection width (L4-02) between 0.0 and 0.5 Hz. If the load slips during stop, make incremental changes of 0.1 Hz
until the load no longer slips.
Sequence Circuit Design for Opening and Closing the Holding Brake
Design the braking sequence as follows:
The brake should release when terminal P2-PC closes in response to the run conditions on the sequence side.
When a fault signal is output, the brake should close. When an up or down command is entered, the brake should release.
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Hoist Application Preset Specifics
on page
Table 4.17 Crane Application (Travel): Parameters and Settings
Table 4.18 Parameters Automatically Saved as Preferred (A2-01 to A2-16)
Signal
Frequency Detection Level Frequency Detection
Width
L4-01
Output
Frequency
Frequency
Detection 2
No.
H2-01
L1-01
L4-01
L6-02
L6-03
73
when using Hoist Application Preset.
Optimum Setting
0: V/f control
0: Operator
3.0 s
3.0 s
0: Heavy Duty
2: 5 kHz
6.0 Hz
30.0 Hz
60.0 Hz
3: Multi-Step Speed 1
4: Multi-Step Speed 2
37: During frequency output
0: Disabled
1: Enabled
1: Triggered when a single phase is lost
1: Always derated
1: Enabled (alarm output)
No.
d1-03
E2-01
H1-05
H1-06
H2-01
L1-01
Refer to Hoist Application Preset Specifics on page 73
Brake Activation Level
Parameter
L4-01 = 1.0 to 3.0 Hz
L4-02 = 0.0 to 0.5 Hz
L4-02
ON
OFF
4.5 Application Presets
Parameter Name
Terminals MA, MB, and MC Function Selection
Motor Overload Protection Selection
Speed Agreement Detection Level
Torque Detection Level 1
Torque Detection Time 1
Parameter Name
Frequency Reference 3
Motor Rated Current
Multi-Function Digital Input Terminal S5 Function
Multi-Function Digital Input Terminal S6 Function
Terminals MA, MB, and MC Function Selection
Motor Overload Protection Selection
for more
Control Mode
V/f
OLV
<1>
O
<2>
Time
OLV for PM
4
O
-
73