E: Motor Parameters - YASKAWA V1000 Series Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
u

E: Motor Parameters

No.
Name
E1-01
Input Voltage Setting
<24>
E1-03
V/f Pattern Selection
E1-04
Max Output Frequency
E1-05
<24>
Max Output Voltage
E1-06
Base Frequency
E1-07
Mid Output Frequency
E1-08
Mid Output Frequency
<24>
Voltage
E1-09
Minimum Output Freq.
E1-10
Minimum Output Freq.
<24>
Voltage
E1-11
Mid Output Frequency 2
<26>
E1-12
Mid Output Frequency
<24>
Voltage 2
<26>
E1-13
<24>
Base Voltage
E2-01
Motor Rated Current
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-04
Number of Motor Poles
Motor Line-to-Line
E2-05
Resistance
E2-06
Motor Leakage Inductance
Motor Iron-Core
E2-07
Saturation Coefficient 1
Motor Iron-Core
E2-08
Saturation Coefficient 2
E2-09
Motor Mechanical Loss
Motor Iron Loss for Torque
E2-10
Compensation
E2-11
Motor Rated Output
Motor Iron-Core
E2-12
Saturation Coefficient 3
E3-01
Motor 2 Control Method
302
Description
E1: V/f Pattern Characteristics
Use E1 parameters to set V/f characteristics for the motor.
This parameter must be set to the power supply voltage. It sets the maximum
and base voltage used by preset V/f patterns (E1-03 = 0 to E) and adjusts levels
used by certain functions.
WARNING! Drive input voltage (not motor voltage) must be set in E1-01 for
the protective features of the drive to function properly. failure to do so may
result in equipment damage and/or death or personal injury.
Selects a preset V/f pattern.
0: 50 Hz Constant torque 1
1: 60 Hz Constant torque 2
2: 60 Hz Constant torque 3 (50 Hz base)
3: 72 Hz Constant torque 4 (60 Hz base)
4: 50 Hz Variable torque 1
5: 50 Hz Variable torque 2
6: 60 Hz Variable torque 3
7: 60 Hz Variable torque 4
8: 50 Hz High starting torque 1
9: 50 Hz High starting torque 2
A: 60 Hz High starting torque 3
B: 60 Hz High starting torque 4
C: 90 Hz (60 Hz base)
D: 120 Hz (60 Hz base)
E: 180 Hz (60 Hz base)
F: Custom V/f. E1-04 through E1-13 settings define the V/f pattern.
These parameters are only applicable when E1-03 is set to F. To set linear V/
f characteristics, set the same values for E1-07 and E1-09. In this case, the
setting for E1-08 will be disregarded. Ensure that the four frequencies are set
according to these rules:
E1-04 ≥ E1-06> E1-07 ≥ E1-09
VACrms Out(V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09 E1-07
Frequency (Hz)
Use E2 parameters to set motor-related data.
Sets the motor nameplate full load current in amperes (A).
Automatically set during Auto-Tuning.
Sets the motor rated slip in Hertz (Hz).
Automatically set during rotational Auto-Tuning.
Sets the magnetizing current of the motor as a percentage of the motor rated
current (E2-01).
Automatically set during rotational Auto-Tuning.
Sets the number of motor poles. Automatically set during Auto-Tuning.
Sets the phase-to-phase motor resistance in ohms.
Automatically set during Auto-Tuning.
Sets the voltage drop due to motor leakage inductance as a percentage of motor
rated voltage.
Automatically set during Auto-Tuning.
Sets the motor iron saturation coefficient at 75% of magnetic flux.
Automatically set during Auto-Tuning.
Sets the motor iron saturation coefficient at 75% of magnetic flux.
Automatically set during Auto-Tuning.
Sets the motor mechanical loss as a percentage of motor rated power (kW).
Adjust in the following circumstances:
• When there is a large amount of torque loss due to motor bearing friction.
• When there is a large amount of torque loss.
Sets the motor iron loss in watts (W).
Sets the motor rated power in kilowatts (kW). Automatically set during
Auto-Tuning.
(1HP = 0.746 kW).
Set to the motor iron saturation coefficient at 130% of magnetic flux.
Automatically set during rotational Auto-Tuning.
E3: Motor 2 V/f Characteristics
Use E3 parameters to set the V/f pattern for a second motor.
0: V/f Control
2: Open Loop Vector (OLV)
155 to 255
40.0 to 400.0
0.0 to 255.0
0.0 to E1-04
0.0 to E1-04
0.0 to 255.0
0.0 to E1-04
0.0 to 255.0
0.0 to E1-04
0.0 to 255.0
E1-06 E1-11 E1-04
0.0 to 255.0
E2: Motor Parameters
10 to 200% of
drive rated
current
0.00 to 20.00
0 to less than
0.000 to 65.000
0.0 to 40.0
E2-07 to 0.50
[E2-07] to 0.75
0.0 to 10.0
0 to 65535
0.00 to 650.00
1.30 to 5.00
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Control Mode
Range
Def.
OL
V/f
V
230 V
S
S
0 to F
F
A
A
60 Hz
<10>
S
S
<21>
230 V
<10>
S
S
60 Hz
<10>
S
S
3.0 Hz
A
A
<2>
18.4 V
<2>
A
A
<12>
1.5 Hz
<2>
S
S
<10>
13.8 V
<2>
A
A
<12>
0.0 Hz
A
A
0.0 V
A
A
0.0 V
A
S
S
S
<57>
<27>
A
A
<57>
A
A
<57>
E2-01
2 to 48
4 poles
A
A
A
A
<57>
<37>
A
A
<57>
0.50
A
0.75
A
0.0%
A
A
<57>
0.40 kW
S
S
<12>
1.30
A
0 or 2
0
A
A
Addr. Hex
Pg.
PM
S
300
83
302
84
S
303
S
304
84
S
305
84
A
306
A
307
84
S
308
A
309
A
30A
A
30B
S
30C
30E
87
30F
310
311
312
313
314
315
316
317
85
318
328
319