Stopping Method Selection: B1-03 - YASKAWA V1000 Series Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

4.6 Basic Drive Setup Adjustments
4.
The motor should accelerate up to 6 Hz while the RUN light is on.
5.
STOP
Press the
key to stop the motor. The RUN light will flash until the motor comes to a complete stop.
Run the Drive using Digital Input Terminals: b1-02 = 1
n
This setting uses the digital input terminals to enter the run command. The factory setting is a 2-wire sequence.
Using a 2-Wire Sequence
Digital Input Terminals
S1
S2
Using a 3-Wire Sequence
When H1-05 (Multi-Function Digital Input Terminal S5 Function Selection) = 0, the functions of terminals S1 and S2 are set to 3-wire sequence, and the
multi-function input terminal becomes forward/reverse run command terminal.
*When terminal S5 is open, the motor rotates forward. When closed, the motor rotates in reverse.
WARNING! When 3-Wire sequence is used, set the drive to 3-Wire sequence before wiring the control terminals and ensure parameter b1-17 is set to 0 (drive does not accept a
run command at power up (default)). If the drive is wired for 3-Wire sequence but set up for 2-Wire sequence (default) and if parameter b1-17 is set to 1 (drive accepts a Run
command at power up), the motor will rotate in reverse direction at power up of the drive and may cause injury.
Note:
Refer to Parameter List on page 293
reverse command to terminal S5.
CAUTION! The motor will begin rotating as soon as the power is switched on. Proper precautions must be taken to ensure that the area around the motor is safe prior to powering
up the drive. Failure to do so may result in minor or moderate injury.
Note: Run by Turning on/off the Power Supply. For safety reasons, the drive is initially set up not to accept a run command at power up (b1-17 = "0"). If a run command is issued
at power up, the RUN indicator LED will flash quickly. To change this and have the run command issued by the drive, change parameter b1-17 to 1.

Stopping Method Selection: b1-03

u
When a Stop command is issued, the drive stops the motor using one of four possible methods.
Ramp to Stop: b1-03 = 0
n
When b1-03 = 0, the motor will decelerate to a stop when a stop command is entered. The deceleration time is set by C1-02 (Deceleration Time 1).
to Acceleration/Deceleration: C1-01 to C1-11 on page
When the output frequency falls below the DC Injection braking start frequency (b2-01) during deceleration, the DC Injection braking current (b2-02)
will be activated for the specified DC Injection time at stop (b2-04).
78
Step
Forward Run
Reverse Run
Figure 4.15 Example Wiring Diagram for 2-Wire Sequence
Stop Switch
Run Switch
(N.C.)
(N.O.)
Figure 4.16 Example Wiring Diagram for 3-Wire Sequence Using Terminal S5
for a list of digital input functions. After performing a 3-wire initialization (A1-03 = "3"), the drive will automatically assign the forward/
80.
ON
Forward Run
Reverse Run
Drive
S1
S2
SC
Digital Input Common
Drive
S1
Run Command
(runs when open)
S2
Stop Command
(stops when closed)
S5
FWD/REV Command
(multi-function input)*
SC
Digital Input Common
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Display/Result
STOP
off
on
flashing
off
OFF
Stop
Stop
Refer