V/F Pattern Default Values; Default Settings Determined By Drive Capacity (O2-04) And Normal / Heavy Duty Selection (C6-01) - YASKAWA V1000 Series Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
L3-21
Decel time at stall prevention during acceleration
<10> Default setting value is dependent on parameter E5-01, Motor Code Selection.
<12> Default setting value is dependent on parameter o2-04, Drive/kVA Selection.
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
No.
E3-04
Maximum output frequency
E3-05
Maximum output voltage
E3-06
Base Frequency
E3-07
Middle output frequency
E3-08
Middle output freq. voltage
E3-09
Minimum output frequency
E3-10
Minimum output voltage
E3-11
Middle output frequency 2
E3-12
Middle output freq. voltage 2
E3-13
Base voltage
<24>
E3-14
Motor 2 Slip compensation gain
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
u

V/f Pattern Default Values

The tables below show the V/f pattern settings default values depending on the control mode (A1-02) and the V/f pattern selection (E1-03 in V/f control).
Table B.3 E1-03 V/f Pattern Settings for Drive Capacity: CIMR-VABA0001 to CIMR-VABA0010; CIMR-VA2A0001 to CIMR-VA2A0010; CIMR-VA4A0001 to CIMR-
No.
U
E1-03
0
1
<55>
E1-04
Hz
50.0
60.0
E1-05
<24>
V
200
200
<61>
E1-06
Hz
50.0
60.0
E1-07
Hz
2.5
3.0
E1-08
<24>
V
16.0
16.0
E1-09
Hz
1.3
1.5
E1-10
<24>
V
12.0
12.0
<61>
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<55> Used as default settings for E1-04 to E1-10 and E2-04 to E2-10
<61> Multiply voltage values by 1.15 for U.S. models (CIMR-VU)
VABA0020;
No.
U
E1-03
0
1
<55>
E1-04
Hz
50.0
60.0
E1-05
<24>
V
200
200
E1-06
Hz
50.0
60.0
E1-07
Hz
2.5
3.0
E1-08
<24>
V
14.0
14.0
E1-09
Hz
1.3
1.5
E1-10
V
7.0
7.0
<24>
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<55> Used as default settings for E1-04 to E1-10 and E2-04 to E2-10
u

Default Settings Determined by Drive Capacity (o2-04) and Normal / Heavy Duty Selection (C6-01)

Table B.5 Single-Phase, 200 V Class Drives
No.
Description
Model CIMR-Vo
C6-01
Normal/Heavy Duty Sel.
o2-04
kVA Selection
E2-11 (E4-11,
Motor rated power
T1-02)
b3-06
Speed Search current 1
b8-04
Energy saving coefficient
C6-02
Carrier frequency
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Description
Table B.2 E3-01 (Motor 2 Control Mode) Dependent Parameters and Default Values
Description
<24>
<24>
<24>
<24>
2
3
4
5
60.0
72.0
50.0
50.0
200
200
200
200
50.0
60.0
50.0
50.0
3.0
3.0
25.0
25.0
16.0
16.0
35.0
50.0
1.5
1.5
1.3
1.3
12.0
12.0
8.0
9.0
Table B.4 E1-03 V/f Pattern Settings for Drive Capacity: CIMR-VABA0012 to CIMR-
CIMR-VA2A0012 to CIMR-VA2A0069; CIMR-VA4A0007 to CIMR-VA4A0038
2
3
4
5
60.0
72.0
50.0
50.0
200
200
200
200
50.0
60.0
50.0
50.0
3.0
3.0
25.0
25.0
14.0
14.0
35.0
50.0
1.5
1.5
1.3
1.3
7.0
7.0
6.0
7.0
Default Settings by Drive Capacity and Normal/Heavy Duty Selection
Unit
Hex.
kW
Setting Range
Resolution
0.00 to 200.00
0.01
Setting Range
Resolution
40.0 to 400.0
0.0 to 255.0
0.0 to 400.0
0.0 to 400.0
0.0 to 255.0
0.0 to 400.0
0.0 to 255.0
0.0 to 400.0
0.0 to 255.0
0.0 to 255.0
0.0 to 2.5
VA4A0005
V/f Control
6
7
8
9
60.0
60.0
50.0
50.0
60.0
200
200
200
200
200
60.0
60.0
50.0
50.0
60.0
30.0
30.0
2.5
2.5
3.0
35.0
50.0
19.0
24.0
19.0
1.5
1.5
1.3
1.3
1.5
8.0
9.0
12.0
13.0
12.0
V/f Control
6
7
8
9
60.0
60.0
50.0
50.0
60.0
200
200
200
200
200
60.0
60.0
50.0
50.0
60.0
30.0
30.0
2.5
2.5
3.0
35.0
50.0
18.0
23.0
18.0
1.5
1.5
1.3
1.3
1.5
6.0
7.0
9.0
11.0
9.0
BA0001
HD
ND
30
0.1
0.2
1
1
481.7
356.9
4
7
B.2 Parameter Table
Control Modes (A1-02)
V/f (0)
OLV (2)
1.00
1.00
Control Modes (E3-01)
V/f (0)
0.1 Hz
60.0
0.1 V
230.0
0.1Hz
60.0
0.1Hz
3.0
0.1 V
18.4
0.1 Hz
1.5
0.1 V
13.8
0.1 Hz
0.0
0.1 V
0.0
0.1 V
0.0
0.1
0.0
A
B
C
D
E
60.0
90.0
120
180
200
200
200
200
60.0
60.0
60.0
60.0
3.0
3.0
3.0
3.0
24.0
16.0
16.0
16.0
1.5
1.5
1.5
1.5
15.0
12.0
12.0
12.0
A
B
C
D
E
60.0
90.0
120
180
200
200
200
200
60.0
60.0
60.0
60.0
3.0
3.0
3.0
3.0
23.0
14.0
14.0
14.0
1.5
1.5
1.5
1.5
13.0
7.0
7.0
7.0
Default Settings
BA0002
HD
ND
HD
31
0.2
0.4
0.4
1
1
1
356.9
288.2
288.2
4
7
4
PM (5)
2.50
OLV (2)
60.0
230.0
60.0
3.0
13.8
0.5
2.9
0.0
0.0
0.0
1.0
OLV
F
60.0
60.0
200
200
60.0
60.0
3.0
3.0
16.0
12.0
1.5
0.5
12.0
2.5
OLV
F
60.0
60.0
200
200
60.0
60.0
3.0
3.0
14.0
11.0
1.5
0.5
7.0
2.0
BA0003
ND
B
32
0.75
1
223.7
7
323