H2-oo
Function
Setting
H2 Parameter Functions Reversed Output
100 to 14D
Switching of 0 to 92
No.
Name
H3-01
Terminal A1 Signal Level Selection
H3-02
Terminal A1 Function Selection
H3-03
<22>
Terminal A1 Gain Setting
H3-04
<22>
Terminal A1 Bias Setting
H3-09
Terminal A2 Signal Level Selection
H3-10
Terminal A2 Function Selection
H3-11
<22>
Terminal A2 Gain Setting
H3-12
<22>
Terminal A2 Input Bias
H3-13
Analog Input Filter Time Constant
<22> Parameter can be changed during run.
<40> The availability of certain parameters depends on the control method used.
H3-oo
Setting
0
Frequency Bias
1
Frequency Gain
Auxiliary Frequency Reference (used as a multi step speed
2
2)
4
Output Voltage Bias
7
Overtorque/Undertorque Detection Level
B
PID Feedback
C
PID Set Point
E
Motor Temperature (PTC input)
F
Not used / Pass-through mode
10
FWD Torque Limit
11
REV Torque Limit
12
Regenerative Torque Limit
15
FWD/REV Torque Limit
16
Differential PID Feedback
No.
Name
Multi-Function Analog Output
H4-01
Terminal AM)
H4-02
Multi-Function Analog Output
<22>
Terminal AM Gain
H4-03
Multi-Function Analog Output
Terminal AM Gain
<22>
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
H2 Multi-Function Digital Output Settings
Reverse the output switching of the multi-function output functions. Set the last two digits of 1oo to reverse the
output signal of that specific function.
Examples:
Setting "108" reverses the output of "During baseblock," which is setting value 08.
Setting "14A" reverses the output of "During KEB operation", which is setting "4A".
Use H3 parameters to set the multi-function analog input terminals.
Sets the input level for terminal A1.
0: 0 to +10 V (lower limit)
1: 0 to +10 V (no lower limit)
Sets the function of terminal A1.
When terminal A1 is not used or is used as a through terminal, this parameter
must be set to "F".
Sets the level of the input value selected in H3-02 when 10V is input at terminal
A1.
Sets the level of the input value selected in H3-02 when 0V is input at terminal
A1.
Sets the input signal level for terminal A2.
0: 0 to +10 V (with lower limit)
1: 0 to +10 V (no lower limit)
2: 4 to 20 mA
3: 0 to 20 mA
Sets the function of terminal A2.
When terminal A2 is not used or is used as a through terminal, this parameter
must be set to "F".
Sets the level of the input value selected in H3-10 when 10 V (20 mA) is input
at terminal A2.
Sets the level of the input value selected in H3-10 when 0 V (0 or 4 mA) is input
at terminal A2.
Sets the primary delay filter time constant for terminals A1 and A2. Used for
noise filtering.
H3 Multi-Function Analog Input Settings
Function
Max output frequency (E1-04).
Same value can be set using H3-02 and H3-10.
Frequency reference (voltage)
Max output frequency (E1-04)
Motor rated voltage (E1-05).
Open Loop Vector: Motor rated torque
V/f control: Drive rated current
10V = 100%
10V = 100%
10 V = 100.00%
Determined by L1-03 and L1-04.
Motor rated torque
Motor rated torque
Motor rated torque
Motor rated torque
10 V = 100%
H4: Multi-Function Analog Outputs
Use H4 parameters to configure the multi-function analog output terminals.
Selects the data to be output through multi-function analog output terminal AM.
Set the desired monitor parameter to the digits available in Uo-oo. For
example, enter "103" for U1-03.
When using this terminal in trough mode or when not using it at all, set "000"
or "031".
Sets terminal AM output level when selected monitor is at 100%.
Maximum output voltage is 10 V.
Sets terminal AM output level when selected monitor is at 0%.
Description
Description
H3: Analog Inputs
Maximum Input Level Possible
Description
B.2 Parameter Table
Control
V/f OL
O
Control
Mode
Range
Def.
V/f OL
PM
V
0, 1
0
A
A
A
0 to 31
0
A
A
A
<40>
-999.9 to 999.9 100.0% A
A
A
-999.9 to 999.9 0.0%
A
A
A
0 to 3
2
A
A
A
Switch between current or voltage inputs by using DIP switch
S1-2 switch on the terminal board.
Refer to I/O
Connections on page
48.
0 to 31
0
A
A
A
<40>
-999.9 to
100.0% A
A
A
1000.0
-999.9 to 999.-
0.0%
A
A
A
0.00 to 2.00
0.03 s
A
A
A
Control Mode
V/f OLV PM
O
O
O
O
O
O
O
O
O
O
Control
Mode
Range
Def.
V/f OL V PM
000 to 999
102
A
A
A
<40>
-999.9 to
100.0%
S
S
S
999.9
-999.9 to
0.0%
A
A
A
999.9
Mode
Pg.
PM
V
O
O
Addr.
Pg.
Hex
410
434
411
412
417
418
419
41A
41B
Pg.
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Addr.
Pg.
Hex
41D
B
41E
41F
309