4.3 The Drive and Programming Modes
Drive Mode
Programming Mode
Drive Mode
Drive Mode Details
n
The following actions are possible in the Drive Mode:
• Run and stop the drive.
• Monitor the operation status of the drive (frequency reference, output frequency, output current, output voltage, etc.).
• View information on an alarm.
• View a history of alarms that have occurred.
Note: Select "Drive Mode" when running. The mode can be switched to any mode (program mode, etc.) other than drive mode while the drive is stopped. However, the drive cannot
be operated in other modes. Return the mode to "Drive Mode" after completing periodic inspection.
Figure 4.4
illustrates changing the default frequency reference of F 0.00 (0 Hz) to F 6.00 (6 Hz) while in Drive Mode. This example assumes the drive
is set to LOCAL.
Note: The drive will not accept a frequency reference set value unless the ENTER key is pressed after the frequency reference is entered. This feature prevents accidental setting of
the frequency reference. By setting o2-05 (Frequency Reference Setting Method Selection) to 1 (Enabled), the drive will accept the frequency reference while it is being
adjusted on the digital operator.
Programming Mode Details
n
The following actions are possible in the programming mode:
62
Output Voltage Reference
(Default setting)
Scroll through o1-01 (User Monitor Selection) until the desired contents appear.
page 293
Monitor Display
STOP
Monitor parameters (U-parameters) are displayed.
89.
Verify Function
STOP
Lists all parameters that have been edited or changed from default settings.
Changes: Verify Menu on page
Setup
STOP
A select list of parameters necessary to get the drive operational quickly.
the Programming Mode on page
(Application Preset).
Parameter Setting
STOP
Allows the user to access and edit all parameter settings.
Auto-Tuning
STOP
Motor parameters are calculated and set automatically.
Frequency Reference
STOP
Returns to the frequency reference display screen.
STOP
Frequency reference
display at power up
STOP
Press to select LOCAL
Press until the frequency
reference becomes 6 Hz
Figure 4.4 Setting the Frequency Reference while in Drive Mode
Refer to Drive Status Monitors: U1-01 to U6-19 on page
64.
63. Note: Parameters to be displayed differ depending on the setting of A1-06
Refer to Application Presets on page
Press to select the
digit to the right
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Refer to Parameter List on
Refer to Verifying Parameter
Refer to The Setup Group within
70.
Refer to Parameter List on page
293.
Refer to Auto-Tuning on page
91.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents