YASKAWA V1000 Series Technical Manual page 307

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

H1-o Setting
Function
20 to 2F
External Fault
30
PID Integral Reset
31
PID Integral Hold
32
Multi-Step Speed Reference 4
34
PID Soft Starter
35
PID Input Switch
40
Forward Run Command (2-wire sequence)
41
Reverse Run Command (2-wire sequence)
42
Run Command (2-wire sequence 2)
43
FWD/REV Command (2-wire sequence 2)
44
Offset Frequency 1 Addition
45
Offset Frequency 2 Addition
46
Offset Frequency 3 Addition
60
DC Injection Braking Command
61
External Search Command 1
62
External Search Command 2
65
KEB Ride-Thru 1 (N.C.)
66
KEB Ride-Thru 1 (N.O.)
67
Communications Test Mode
68
High-Slip Braking
6A
Drive Enable
75
Up 2 Command
76
Down 2 Command
7A
KEB Ride-Thru 2 (N.C.)
7B
KEB Ride-Thru 2 (N.O.)
7C
Short-Circuit Braking (N.O.)
7D
Short-Circuit Braking (N.C.)
7E
Forward/Reverse Detection
9F
DriveWorksEZ enable
No.
Name
H2-01
Terminal MA, MB and MC Function Selection (relay)
H2-02
Terminal P1 Function Selection (open-collector)
H2-03
Terminal P2 Function Selection (open-collector)
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
H1 Multi-Function Digital Input Selections
20: N.O., Always Detected, Ramp To Stop
21: N.C., Always Detected, Ramp To Stop
22: N.O., During Run, Ramp To Stop
23: N.C., During Run, Ramp To Stop
24: N.O., Always Detected, Coast To Stop
25: N.C., Always Detected, Coast To Stop
26: N.O., During Run, Coast To Stop
27: N.C., During Run, Coast To Stop
28: N.O., Always Detected, Fast-stop
29: N.C., Always Detected, Fast-stop
2A: N.O., During Run, Fast-stop
2B: N.C., During Run, Fast-stop
2C: N.O., Always Detected, Alarm Only (continue running)
2D: N.C., Always Detected, Alarm Only (continue running)
2E: N.O., During Run, Alarm Only (continue running)
2F: N.C., During Run, Alarm Only (continue running)
Closed: Resets the PID control integral value.
Closed: Maintains the current PID control integral value.
Used to select Multi-Step Speeds set in d1-01 to d1-16
Closed: Disables the PID soft starter b5-17.
Closed: Inverses the PID input signal
Open: Stop
Closed: Forward run
Note: Can not be set together with Settings 42 or 43.
Open: Stop
Closed: Reverse run
Note: Can not be set together with Settings 42 or 43.
Open: Stop
Closed: Run
Note: Can not be set together with Settings 40 or 41.
Open: Reverse
Closed: Forward
Note: Can not be set together with Settings 40 or 41.
Closed: Adds d7-01 to the frequency reference.
Closed: Adds d7-02 to the frequency reference.
Closed: Adds d7-03 to the frequency reference.
Closed: Triggers DC Injection Braking (b2-02)
Closed: Activates Current Detection Speed Search from the max. output frequency (E1-04) if
b3-01=0. Activates Speed Estimation Type Speed search if b3-01 =1.
Closed: Activates Current Detection Speed Search from the frequency reference b3-01=0.
Activates Speed Estimation Type Speed search if b3-01 =1.
Open: KEB Ride-Thru 1 enabled
Closed: Normal operation
Open: Normal operation
Closed: KEB Ride-Thru 1 enabled
Tests the MEMOBUS/Modbus RS-485/422 interface.
Closed: High-Slip braking is executed. Drive stops.
Open: Drive disabled.
If this input is opened during run, then the drive will stop as specified by parameter b1-03.
Closed: Ready for operation.
Open: Maintains the current frequency reference
Closed: Increases or decreases the frequency reference.
UP 2 and Down 2 commands must be set in combination with each other. The frequency reference
source must be assigned to the operator (b1-01 = "0").
Open: KEB Ride-Thru 2 enabled
Closed: Normal operation
Open: Normal operation
Closed: KEB Ride-Thru 2 enabled
Open: Normal operation
Closed: Short-Circuit Braking
Direction of rotation detection (for Simple V/f w/PG)
Open: DWEZ enabled
Closed: DWEZ disabled
Description
H2: Multi-Function Digital Outputs
Use H2 parameters to assign functions to the multi-function digital outputs.
Refer to H2 Multi-Function Digital Output Settings on page
308
for a description of setting values.
Description
Range
Def.
E
0 to 192
<40>
0
2
B.2 Parameter Table
Control Mode
Pg.
V/f OLV PM
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
-
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
-
-
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
-
-
O
-
-
O
O
-
-
O
O
O
Control
Mode
Addr.
Pg.
Hex
V/f OL V PM
A
A
A
40B
A
A
A
40C
A
A
A
40D
B
307

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents