Verifying Parameter Changes: Verify Menu - YASKAWA A1000 Technical Manual

High performance vector control drive type: cimr-a series models: 200 v class: 0.55 to 110 kw, 400 v class: 0.55 to 630 kw
Hide thumbs Also See for A1000:
Table of Contents

Advertisement

4.3 The Drive and Programming Modes
 Verifying Parameter Changes: Verify Menu
The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. It helps determine
which settings have been changed, and is particularly useful when replacing a drive. If no settings have been changed, the
Verify Menu will read "None". The Verify Menu also allows users to quickly access and re-edit any parameters settings
that have been changed.
Note: The Verify Menu will not display parameters from the A1 group (except for A1-02) and E5-01 even if those parameters have
been changed from their default settings.
The following example is a continuation of the steps above. Here, parameter C1-02 is accessed using the Verify Menu,
and is changed again from 10.0 s to 20.0 s.
To check the list of edited parameters:
1.
Turn on the power to the drive. The initial display appears.
2.
Press
or
Press
to enter the list of parameters that have been edited from their original default settings.
3.
If parameters other than C1-02 have been changed, use the
4.
Press the
key to access the setting value. Left digit flashes.
106
Step
until the display shows the top of the Verify Menu.
or
key to scroll until C1-02 appears.
YASKAWA ELECTRIC SIEP C710616 27G YASKAWA AC Drive A1000 Technical Manual
Display/Result
- MODE -
DRV
Rdy
FREF (OPR)
U1-01= 0.00Hz
U1-02= 0.00Hz
LSEQ
U1-03= 0.00A
LREF
JOG
FWD
FWD/REV
- MODE -
PRG
Modified Consts
Modified
X Parameters
HELP
FWD
DATA
- VERIFY - PRG
Rdy
Accel Time 1
C1-02
= 20.0sec
(0.0~6000.0)
"10.0sec"
Home
FWD
DATA
- VERIFY - PRG
Rdy
Accel Time 1
C1-01=0020.0sec
(0.0~6000.0)
"10.0sec"
Home
FWD
DATA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents