YASKAWA V1000 Series Technical Manual page 321

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
Name
Cumulative Operation Time at
U3-18
8th Most Recent Fault
Cumulative Operation Time at
U3-19
9th Most Recent Fault
Cumulative Operation Time at
U3-20
10th Most Recent Fault
U4-01
Accumulated Operation Time
U4-02
Number of Run Commands
U4-03
Cooling Fan Operation Time
U4-05
Capacitor Maintenance
U4-07
IGBT Maintenance
U4–08
<60>
Heatsink Temperature
U4-09
LED Check
U4-10
kWH, Lower 4 Digits
U4-11
kWH, Upper 5 Digits
U4-13
Peak Hold Current
U4-14
Peak Hold Output Frequency
Motor Overload Estimate
U4-16
(OL1)
Frequency Reference Source
U4-18
Selection
Frequency Reference from
U4-19
MEMOBUS/Modbus Comm.
U4-20
Option Frequency Reference
Run Command Source
U4-21
Selection
MEMOBUS/Modbus
U4-22
Communications Reference
U4-23
Option Card Reference
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Description
Displays the cumulative operation time at the eighth most recent fault. No signal output available
Displays the cumulative operation time at the ninth most recent fault.
Displays the cumulative operation time at the tenth most recent fault.
U4: Maintenance Monitors
Use U4 parameters to display drive maintenance information.
Displays the cumulative operation time of the drive. The value for the
cumulative operation time counter can be set in parameter o4-01. Use
parameter o4-02 to determine if the operation time should start as soon
as the power is switched on or only while the run command is present.
The maximum number displayed is 99999, after which the value is reset
to 0.
Displays the number of times the run command is entered. Reset the
number of run commands using parameter o4-13. This value will reset
to 0 and start counting again after reaching 65535.
Displays the cumulative operation time of the cooling fan. The default
value for the fan operation time is set to parameter o4-03. This value will
reset to 0 and start counting again after reaching 65535.
Displays main circuit capacitor usage time in in percent of their expected
performance life. Parameter o4-06 resets this monitor.
Displays IGBT usage time as a percent of expected performance life.
One of the multi-function contact outputs can be set to close when the
value reaches 50% (H2-oo = 2F), triggering an alarm. One of the multi-
function contact outputs can be set to close when the value reaches 90%
(H2-oo = 10), triggering an alarm. Parameter o4-09 resets this monitor.
Monitors the heatsink for the drive.
Lights all segments of the LED to verify that the display is working
properly.
Monitors the drive output power. The value is shown as a 9 digit number
displayed across two monitor parameters, U4-10 and U4-11.
Example:
12345678.9 kWh is displayed as:
U4-10: 678.9 kWh
U4-11: 12345 MWh
Analog monitor: No output signal available.
Displays the peak hold current during run.
Displays the output frequency when operating at the peak hold current. 10 V: Max frequency
100% = OL1 detection level
Displays the source for the frequency reference as XY-nn.
X: indicates which reference is used:
1 = Reference 1 (b1-01)
2 = Reference 2 (b1-15)
Y-nn: indicates the reference source
0-01 = Operator (d1-01)
1-01 = Analog (terminal A1)
1-02 = Analog (terminal A2)
2-02 to 17 = Multi-step speed (d1-02 to 17)
3-01 = MEMOBUS/Modbus comm.
4-01 = Option
5-01 = Pulse Input
6-01 = CASE
7-01 = DWEZ
Displays the frequency reference provided by MEMOBUS/Modbus
(decimal)
Displays the frequency reference input by an option card (decimal).
Displays the source for the Run command as XY-nn.
X: Indicates which Run source is used:
1 = Reference 1 (b1-02)
2 = Reference 2 (b1-16)
Y: Input power supply data
0 = Operator
1 = External terminals
2 = Not used
3 = MEMOBUS/Modbus communications
4 = Option
5 = Not used
6 = CASE
7 = DWEZ
nn: Run command limit status data
00: No limit status.
01: Run command was left on when stopped in the PRG mode.
02: Run command was left on when switching from local to remote
operation.
03: Waiting for the soft charge bypass contactor after the power is
switched on (UV or UV1 flashes after 10 seconds).
04: Waiting for "Run Command Prohibited" time period to end.
05: Fast-stop (digital input (H1-oo = 15), operator)
06: b1-17 (run command given at power-up).
07: During Baseblock while coast to stop with timer
08: Frequency reference is below minimal reference during base block
09: Waiting for Enter command
Displays the drive control data set by MEMOBUS/Modbus
communications register No. 0001H as a 4 digit hexadecimal number.
Displays drive control data set by an option card as a 4 digit hexadecimal
number.
Analog Output Level
Unit
1 h
No signal output available
1 h
No signal output available
1 h
No signal output avail.
1 h
No signal output avail.
No signal output avail.
1H
No signal output avail.
1%
No signal output avail.
1%
No signal output avail.
1°C
No signal output avail.
kWh
No signal output avail.
MWh
10 V: Motor rated current
0.01A
0.01Hz
100% = OL1 detection level
0.1%
B.2 Parameter Table
Control Mode
Addr. Hex
V/f OLV PM
A
A
A
811E
A
A
A
812
A
A
A
813
A
A
A
4C
A
A
A
76
A
A
A
67
A
A
A
7C
A
A
A
7D7
A
A
A
68
A
A
A
3C
A
A
A
5C
A
A
A
5D
A
A
A
7CF
A
A
A
7D0
A
A
A
7D8
A
A
A
7DA
A
A
A
7DB
A
A
A
7DD
A
A
A
7DD
B
A
A
A
7DE
A
A
A
7DF
321