5.5 E: Motor Parameters
No.
E5-03
Motor Rated Current (PM OLV)
Note: The default value is determined by the motor code set to E5-01. Setting units are determined by drive capacity. 7.5 kW or less: 0.01 A, 11 kW or greater: 0.1 A
E5-04: Number of Motor Poles (PM OLV)
n
Sets the number of motor poles.
No.
E5-04
Number of Motor Poles (PM OLV)
Note: The default value is determined by the motor code set to E5-01. This parameter is not reset when the drive is initialized using A1-03.
E5-05: Motor Armature Resistance (PM OLV)
n
Set the resistance for each motor phase in units of 0.001 W.
No.
E5-05
Motor Armature Resistance (PM OLV)
Note: The default value is determined by the motor code set to E5-01. This parameter is not reset when the drive is initialized using A1-03.
E5-06: Motor d Axis Inductance (PM OLV)
n
Sets the d axis inductance in units of 0.01 mH.
No.
E5-06
Motor d Axis Inductance (PM OLV)
Note: The default value is determined by the motor code set to E5-01. This parameter is not reset when the drive is initialized using A1-03.
E5-07: Motor q Axis Inductance (PM OLV)
n
Sets the q axis inductance in units of 0.01 mH.
No.
E5-07
Motor q Axis Inductance (PM OLV)
Note: The default value is determined by the motor code set to E5-01. This parameter is not reset when the drive is initialized using A1-03.
E5-09: Motor Induction Voltage Constant 1 (PM OLV)
n
Set the inductance voltage for each motor phase in units of 0.1 mV/(rad/min) [electrical angle]. Set this parameter when using an SSR1 series IPM motor
with derated torque or an SST4 series motor with constant torque.
E5-24: Motor Induction Voltage Parameter 2 (PM OLV)
n
Set the inductance voltage for each motor phase in units of 0.1 mV/(r/min) [mechanical angle]. Set this parameter when using an SMRA series pico motor.
Note: Ensure that E5-09 = 0 when setting parameter E5-24.
An alarm will be triggered, however, if both E5-09 and E5-24 are set 0, or if neither parameter is set to 0.
No.
E5-09
Motor Induction Voltage Constant 1 (PM OLV)
E5-24
Motor Induction Voltage Parameter 2 (PM OLV)
Note: The default value is determined by the motor code set to E5-01. This parameter is not reset when the drive is initialized using A1-03.
154
Parameter Name
Parameter Name
Parameter Name
Parameter Name
Parameter Name
Parameter Name
Setting Range
10 to 200% of drive rated current
Setting Range
2 to 48
Setting Range
0.000 to 65.000
Setting Range
0.00 to 300.00
Setting Range
0.00 to 600.00
Setting Range
0.0 to 2000.0
0.0 to 2000.0
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Default
Determined by E5-01
Default
Determined by E5-01
Default
Determined by E5-01
Default
Determined by E5-01
Default
Determined by E5-01
Default
Determined by E5-01
Determined by E5-01