T: Motor Tuning; U: Monitors - YASKAWA V1000 Series Technical Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
r1-17
DWEZ Connection Parameter 9 (upper)
r1-18
DWEZ Connection Parameter 9 (lower)
r1-19
DWEZ Connection Parameter 10 (upper)
r1-20
DWEZ Connection Parameter 10 (lower)
r1-21
DWEZ Connection Parameter 11 (upper)
r1-22
DWEZ Connection Parameter 11 (lower)
r1-23
DWEZ Connection Parameter 12 (upper)
r1-24
DWEZ Connection Parameter 12 (lower)
r1-25
DWEZ Connection Parameter 13 (upper)
r1-26
DWEZ Connection Parameter 13 (lower)
r1-27
DWEZ Connection Parameter 14 (upper)
r1-28
DWEZ Connection Parameter 14 (lower)
r1-29
DWEZ Connection Parameter 15 (upper)
r1-30
DWEZ Connection Parameter 15 (lower)
r1-31
DWEZ Connection Parameter 16 (upper)
r1-32
DWEZ Connection Parameter 16 (lower)
r1-33
DWEZ Connection Parameter 17 (upper)
r1-34
DWEZ Connection Parameter 17 (lower)
r1-35
DWEZ Connection Parameter 18 (upper)
r1-36
DWEZ Connection Parameter 18 (lower)
r1-37
DWEZ Connection Parameter 19 (upper)
r1-38
DWEZ Connection Parameter 19 (lower)
r1-39
DWEZ Connection Parameter 20 (upper)
r1-40
DWEZ Connection Parameter 20 (lower)
u

T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance
No.
Name
T1-00
Motor Selection 1/2
Auto-Tuning Mode
T1-01
Selection
T1-02
Motor Rated Power
T1-03
<24>
Motor Rated Voltage
T1-04
Motor Rated Current
T1-05
Motor Base Frequency
T1-06
Number of Motor Poles
T1-07
Motor Base Speed
T1-11
Motor Iron Loss
<12> Default setting value is dependent on parameter o2-04, Drive/kVA Selection.
<24> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<54> The available tuning methods depend on control mode. Select values 2 or 3 in V/f control, 0 or 2 in OLV control, and 2 for Motor 2 control.

U: Monitors

u
Monitor parameters allow the user to view drive status, fault information, and other information about drive operation.
No.
Name
U1-01
Frequency Reference
U1-02
Output Frequency
U1-03
Output Current
318
Parameter 9 for connecting DWEZ (upper).
Parameter 9 for connecting DWEZ (lower).
Parameter 10 for connecting DWEZ (upper).
Parameter 10 for connecting DWEZ (lower).
Parameter 11 for connecting DWEZ (upper).
Parameter 11 for connecting DWEZ (lower).
Parameter 12 for connecting DWEZ (upper).
Parameter 12 for connecting DWEZ (lower).
Parameter 13 for connecting DWEZ (upper).
Parameter 13 for connecting DWEZ (lower).
Parameter 14 for connecting DWEZ (upper).
Parameter 14 for connecting DWEZ (lower).
Parameter 15 for connecting DWEZ (upper).
Parameter 15 for connecting DWEZ (lower).
Parameter 16 for connecting DWEZ (upper).
Parameter 16 for connecting DWEZ (lower).
Parameter 17 for connecting DWEZ (upper).
Parameter 17 for connecting DWEZ (lower).
Parameter 18 for connecting DWEZ (upper).
Parameter 18 for connecting DWEZ (lower).
Parameter 19 for connecting DWEZ (upper).
Parameter 19 for connecting DWEZ (lower).
Parameter 20 for connecting DWEZ (upper).
Parameter 20 for connecting DWEZ (lower).
Description
Selects which set of motor parameters are used and set during Auto-Tuning. If Motor
2 selection (H1-oo = 16) is not selected, this parameter will not be displayed.
1: 1st Motor - E1 to E2
2: 2nd Motor - E3 to E4
(this selection is not displayed if motor 2 has not been selected)
Selects the Auto-Tuning mode.
0: Rotational Auto-Tuning
2: Stationary Auto-Tuning, Terminal resistance only,
3: Rotational Auto-Tuning for V/f control (necessary for Energy Savings and Speed
Estimation type speed search)
Sets the motor rated power in kilowatts (kW).
Note: If motor power is given in horsepower, power in kW can be calculated using the
following formula: kW = HP x 0.746.
Sets the motor rated voltage in volts (V).
Sets the motor rated current in amperes (A).
Sets the base frequency of the motor in Hertz (Hz).
Sets the number of motor poles.
Sets the base speed of the motor in revolutions per minute r/min (RPM).
Provides the iron loss for determining the Energy Saving coefficient.
The value set to E2-10 (motor iron loss) when the power is cycled. If T1-02 is changed,
an initial value valid for the selected capacity will be shown.
Description
U1: Operation Status Monitors
Use U1 monitors to display the operation status of the drive.
Monitors the frequency
Displays the output voltage. Display units are determined by o1-03.
Displays the output current.
Description
Analog Output Level
10 V: Max frequency
10 V: Max frequency
10 V: Drive rated current
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Control
Mode
Range
Def.
V/f OL V PM
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
0000 to FFFF(H)
0
A
A
Control
Mode
Range
Def.
OL
V/f
V
1, 2
1
A
A
2 or 3 in V/f
0 or 2 in
0, 2, 3
A
A
<54>
OLV2 for
Motor 2
0.00 to 650.00
0.40 kW
A
A
0.0 to 255.5
200.0 V
A
A
10 to 200% of
drive rated
A
A
<12>
current
0.0 to 400.0
60.0 Hz
A
A
2 to 48
4
A
A
0 to 24000
1750 r/min
A
A
14W
A
0 to 65535
These values differ depending on the motor code
value and motor parameter settings.
Control Mode
Unit
V/f OLV PM
0.01Hz
A
0.01Hz
A
<27>
0.01A
A
Addr. Hex Pg.
A
1850
A
1851
A
1852
A
1853
A
1854
A
1855
A
1856
A
1857
A
1858
A
1859
A
185A
A
185B
A
185C
A
185D
A
185E
A
185F
A
1860
A
1861
A
1862
A
1863
A
1864
A
1865
A
1866
A
1867
Addr.
Pg.
Hex
PM
700
701
702
703
704
705
706
707
70B
Addr. Hex
A
A
40
A
A
41
A
A
42