Table 9–1. Protection Condition and Event Status Registers
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21-31
M330461-01 Rev A
Hex Value
Description
0x01
Constant Voltage Operation
0x02
Constant Current Operation
0x04
Constant Power Operation
0x08
Overvoltage Protection Fault
0x10
Over Temperature Fault
0x20
External Shutdown
0x40
Foldback Mode Operation
0x80
Remote Programming Error
0x100
Fan Fault
0x200
Line Drop Fault
0x400
DC Module Fault
0x800
PFC Fault
0x1000
OCP Fault
0x2000
AUX Supply Fault
0x4000
Line Status Changed
0x8000
Parallel Cable Fault
0x10000
Salve System Fault
0x20000
Not Used
0x40000
Remote Sense Fault
0x80000
Regulation Fault
0x100000
Current Feedback Fault
Not Used (Always returns zero for these bits)
External User Control Signal Connector