Ethernet Configuration and Remote Programming
To change:
Description: you may change the default factory setting to something more
meaningful to your current setup.
To change:
TCP/IP Configuration: the power supply can operate in DHCP or Static IP
Configuration.
You may statically assign an IP address as well as configure other Ethernet/LAN
parameters (Subnet Mask and Gateway) or use DHCP for automatic assignment of
an IP address.
Static IP Configuration: Click the radio button next to Static IP to manually configure
some or all of the following the Ethernet/LAN parameters:
DHCP Configuration:
acquisition from the DHCP server.
Auto IP:
will assign itself an IP address in the range from 169.254.0.1 to 169.254.255.254 with
a subnet mask of 255.255.0.0.
Click in the box next to Auto IP to check (enable Auto IP); click again to uncheck
(disable Auto IP) (Refer to Figure 6-11)
6-16
Type the new name (15 characters maximum) in the blank field
provided and click Apply to update (or make all desired changes
before clicking Apply).
Type your customized description, up to 36 characters, in the blank
field provided, and click Apply to update (or make all desired changes
before clicking Apply).
IP Address – input any standard IP address. (Factory setting is
192.168.0.200). Click Apply and enter the new IP address in LXI web
browser to view the Home page of the power supply. Refer to Figure 6-10.
If you have changed the network portion of the IP address, it may be
necessary to alter the network settings of your attached computer to
reconnect to the power supply.
Subnet Mask – input a value that identifies which network segment your
power supply is on, consisting of 4 whole numbers, each ranging from 0
through 255, separated by periods. (Factory setting is 255.0.0.0, a class-C
network subnet mask). Click Apply to update (or make all desired changes
before clicking Apply).
Gateway – input the IP Address of any gateway that stands between the
instrument and any other network entities that communicate with the power
supply. (No factory setting). Click Apply to update (or make all desired
changes before clicking Apply).
Click the radio button next to DHCP, for dynamic address
If it is enabled, when there is no DHCP server available, the power supply
Asterion DC Series Programming
M330461-01 Rev A