Ametek ASTDC60D1C-E00 Programming Manual page 115

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

Asterion DC Series Programming
Command
CALibrate
:INITial:POWer <NRf>
CALibrate
:INITial:POWer?
CALibrate
:INITial:POWer:LIMit <NRf>
CALibrate
:INITial:POWer:LIMit?
CALibrate
:INITial:POWer:PROGram
<string>
CALibrate
:INITial:POWer:PROGram?
CALibrate
:INITial:POWer:PROGram:FSC
<NRf>
CALibrate
:INITial:POWer:PROGram:FSC?
CALibrate
:INITial:POWer:PROGram:FSCR
<NRf>
CALibrate
:INITial:POWer:PROGram:FSCR?
CALibrate
:INITial:POWer:MONitor
CALibrate
:INITial:POWer:MONitor:FSC
<NRf>
CALibrate
:INITial:POWer:MONitor:FSC?
CALibrate
:INITial:MEASure:CURRent:AVEra
ge <NR1>
CALibrate
:INITial:MEASure:CURRent:AVEra
ge?
CALibrate
:INITial:MEASure:VOLTage:AVEra
ge <NR1>
M330461-01 Rev A
External User Control Signal Connector
Description
Sets the power-on default value of
power.
Returns the default value of power-
on power.
Sets the power-on default value of
power limit.
Returns the default value of power-
on power limit.
Sets the power-on default setting for
output power programming. Valid
arguments - INT, EXT or ADD
Returns the default setting of power-
on output power programming.
Sets the power-on default voltage
value for full scale power from
external analog programming.
Returns the power-on default full
scale voltage value.
Sets the power-on default resistance
value for full scale power from
external analog programming.
Returns the power-on default full
scale resistance value.
Initializes the power monitor
(PMON) signal calibration
Sets the power-on default voltage on
PMON signal for full scale output
power.
Returns the power-on default full
scale voltage value on PMON
signal.
Sets the number of readings to
average together when returning the
current value with the MEAS:CURR?
command to reduce noise in the
readback readings. Enter a value of
3 to 9, with the value of 3 (factory
default) providing the fastest
response time in the readings, but
less rejection of noise.
Returns the number 3 to 9 to
indicate the number of readings to
average together when taking a
current reading.
Sets the number of readings to
average together when returning the
voltage value with the MEAS:VOLT?
command to reduce noise in the
readback readings. Enter a value of
1 to 10, with the value of 1 (factory
default) providing the fastest
response time in the readings, but
less rejection of noise.
SCPI
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
9-33

Hide quick links: