SCPI Status Implementation
Command
CALibrate
:OUTPut:CURRent:EXT420MA:OFFSE
T <NRf>
CALibrate
:OUTPut:CURRent:EXT420MA:FSC
<NRf>
CALibrate
:OUTPut:CURRent:MON:OFFSET
<NRf>
CALibrate
:OUTPut:CURRent:MON:FSC <NRf>
CALibrate
:OUTPut:VOLTage
CALibrate
:OUTPut:VOLTage:CALCulate
CALibrate
:OUTPut:VOLTage:DAC <NR1>
CALibrate
:OUTPut:VOLTage:FIVEPOINT
<1|2|3|4|5> <NRf>
CALibrate
:OUTPut:VOLTage:FIVEPOINT?
CALibrate
:OUTPut:VOLTage:GAIN <NRf>
CALibrate
:OUTPut:VOLTage:GAIN?
CALibrate
:OUTPut:VOLTage:OFFSet <NRf>
CALibrate
:OUTPut:VOLTage:OFFSet?
CALibrate
:OUTPut:VOLTage:EXTV:OFFSET
<NRf>
CALibrate
:OUTPut:VOLTage:EXTV:FSC <NRf> Sets the calibration full-scale point
CALibrate
:OUTPut:VOLTage:EXTI:OFFSET
<NRf>
CALibrate
:OUTPut:VOLTage:EXTI:FSC <NRf> Sets the calibration full-scale point
CALibrate
:OUTPut:VOLTage:EXT420MA:OFFSE
T <NRf>
CALibrate
:OUTPut:VOLTage:EXT420MA:FSC
<NRf>
CALibrate
:OUTPut: VOLTage:MON:OFFSET
<NRf>
CALibrate
:OUTPut:VOLTage:MON:FSC <NRf>
9-36
Asterion DC Series Programming
Description
Sets the calibration Offset point for
current programming from external
4-20mA source
Sets the calibration full-scale point
for current programming from
external 4-20mA source
Sets the calibration Offset point for
current monitor signal
Sets the calibration full-scale point
for current monitor signal
Calibrate Output Voltage subsystem
Calculates the value of the gain and
offset for output voltage.
Sets the output of the output voltage
D/A converter.
Sets output voltage value for each
calibration point (1-5)
Returns the entered values for 5-
point calibration.
Sets the value of the gain for the
output voltage.
Returns the value of the gain for the
output voltage.
Sets the value of the offset for the
output voltage.
Returns the value of the offset for
the output voltage.
Sets the calibration Offset point for
voltage programming from external
voltage source
for voltage programming from
external voltage source
Sets the calibration Offset point for
voltage programming from external
resistance source
for voltage programming from
external resistance source
Sets the calibration Offset point for
voltage programming from external
4-20mA source
Sets the calibration full-scale point
for voltage programming from
external 4-20mA source
Sets the calibration Offset point for
voltage monitor signal
Sets the calibration full-scale point
for voltage monitor signal
SCPI
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
M330461-01 Rev A