Ametek ASTDC60D1C-E00 Programming Manual page 114

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

SCPI Status Implementation
Command
CALibrate
:INITial:CURRent:PROGram:FSCR? Returns the power-on default full
CALibrate
:INITial:CURRent:PROGram?
CALibrate
:INITial:CURRent:MONitor
CALibrate
:INITial:CURRent:MONitor:FSC
<NRf>
CALibrate
:INITial:CURRent:MONitor:FSC?
CALibrate
:INITial:VOLTage <NRf>
CALibrate
:INITial:VOLTage?
CALibrate
:INITial:VOLTage [:AMPLitude]
<NRf>
CALibrate
:INITial:VOLTage [:AMPLitude]? Returns the power-on default
CALibrate
:INITial:VOLTage:PROTection
<NRf>
CALibrate
:INITial:VOLTage:PROTection?
CALibrate
:INITial:VOLTage:LIMit <NRf>
CALibrate
:INITial:VOLTage:LIMit?
CALibrate
:INITial:VOLTage:PROGram?
CALibrate
:INITial:VOLTage:PROGram
CALibrate
:INITial:VOLTage:PROGram:SOURc
e <string>
CALibrate
:INITial:VOLTage:PROGram:SOURc
e?
CALibrate
:INITial:VOLTage:PROGram:FSC
<NRf>
CALibrate
:INITial:VOLTage:PROGram:FSC?
CALibrate
:INITial:VOLTage:PROGram:FSCR
<NRf>
CALibrate
:INITial:VOLTage:PROGram:FSCR? Returns the power-on default full
CALibrate
:INITial:VOLTage:MONitor
CALibrate
:INITial:VOLTage:MONitor:FSC
<NRf>
CALibrate
:INITial:VOLTage:MONitor:FSC?
9-32
Asterion DC Series Programming
Description
scale resistance value.
Returns the default setting of power-
on output current programming.
Initializes the current monitor
(IMON) signal calibration
Sets the power-on default voltage on
IMON signal for full scale output
current.
Returns the power-on default full
scale voltage value on IMON signal.
Sets the power-on default voltage.
Returns the default value of power-
on voltage
Sets the power-on default voltage.
voltage.
Sets the power-on default value of
the overvoltage protection.
Returns the default value of the
power-on overvoltage protection.
Sets the power-on default value of
voltage limit.
Returns the default value of power-
on current limit.
Returns the default setting of power-
on output voltage programming.
Program subsystem
Sets the power-on default source for
external analog programming for
Voltage Current and Power. Valid
arguments- VOLT, CURR or MA420
Returns the default power-on source
for external analog programming.
Sets the power-on default voltage
value for full scale voltage from
external analog programming.
Returns the power-on default full
scale voltage value.
Sets the power-on default resistance
value for full scale voltage from
external analog programming.
scale resistance value.
Initializes the voltage monitor
(VMON) signal calibration
Sets the power-on default voltage on
VMON signal for full scale output
voltage.
Returns the power-on default full
scale voltage value on VMON
signal.
SCPI
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
M330461-01 Rev A