Remote Output On/Off Control By External Source - Ametek ASTDC60D1C-E00 Programming Manual

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

Asterion DC Series Programming

Remote Output ON/OFF Control by External Source

8.6.2
Application of AC/DC voltage between Pins 1 and 16, or TTL/CMOS voltage between
Pins 31 and 16, will turn on the power supply; this interface is opto-isolated from circuit
common. See Figure 8-15 and Figure 8-16 for connection requirements.
Figure 8-15 Remote Output On/Off Using Isolated AC or DC Source
Figure 8-16 Remote Output On/Off Using Isolated TTL/CMOS Source
M330461-01 Rev A
External User Control Signal Connector
ON/OFF_HV
1
16
ON/OFF_ISO
31
16
RTN_HV
AC or DC
Source
8-25