Ametek ASTDC60D1C-E00 Programming Manual page 100

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

SCPI Status Implementation
Command
SOURce:VOLTage:PROTection:PROGram:FSC?
SOURce:VOLTage:RAMP <NRf> <NRf>
SOURce:VOLTage:RAMP?
SOURce:VOLTage:RAMP:ABORt
SOURce:VOLTage:ALL?
SOURce:VOLTage:RAMP:HTRIGgered <NRf><NRf>
SOURce:VOLTage:RAMP:HTRIGgered?
SOURce:VOLTage:RAMP:TRIGgered <NRf> <NRf>
SOURce:VOLTage:RAMP:TRIGgered?
SOURce:VOLTage:TRIGgered <NRf>
SOURce:VOLTage:TRIGgered?
SOURce:VOLTage:TRIGgered:CLEar
SOURce:VOLTage:TRIGgered:[AMPLitude] <NRf>
SOURce:VOLTage:TRIGgered:[AMPLitude]?
SOURce:VOLTage:PROGram <string>
SOURce:VOLTage:PROGram?
SOURce:VOLTage:PROGram:FSC <NRf>
SOURce:VOLTage:PROGram:FSC?
SOURce:VOLTage:PROGram:FSCR <NRf>
9-18
Asterion DC Series Programming
Description
external Over voltage Programming Mode. Valid
voltage Range is from 2 to 10V.
Returns the Full-scale Voltage, at which Full
Scale
Over
voltage
programmed.
Sets the output voltage to ramp from the present
value to the specified value (first argument) in the
specified time (second argument).
Function Description Section 9.5.3.
Returns 1 if the ramp is in progress, and 0 if the
ramp is completed.
Aborts ramping and clears trigger mode.
Returns the ramping status.
Sets the value of the output voltage ramp to be
implemented when the hardware trigger is
received.
Returns the value of the output voltage ramp to
be implemented when the hardware trigger is
received.
Sets the output voltage to ramp from the present
value to the specified value (first argument) in the
specified time (second argument) upon the
trigger command. See description of the Ramp
Function below.
Returns the output voltage to ramp
Sets the output voltage to the values stored by
sending the command TRIGger:TYPe 1 or 3.
Returns the voltage level that will be set upon
receipt of the trigger.
Clears the value stored by the
SOURce:VOLTage:TRIGger:AMPLitude
command.
Sets the output voltage to the values stored by
sending the command TRIGger:TYPe 1 or 3.
Returns the stored value of the output current to
be set when the SOURce:VOLTage:TRIGGered
command is sent.
Changes the Voltage programming mode of the
supply. Valid arguments are INT/0 (Internal
Digital Voltage programming)
EXT/1 (External analog Voltage programming)
ADD/2 (Add Internal and External Voltage
programming values)
Returns the setting of Voltage programming
mode
Sets the Full Scale voltage, at which Full scale
Voltage will be programmed in external Voltage
programming
Mode
programming source. Valid Range is from 2 to
10V.
Returns the Full-scale Voltage, at which Full
scale Voltage will be programmed.
Sets the Full Scale resistance, at which Full
scale Voltage will be programmed in external
Voltage
programming
trip
point
will
be
See Ramp
with
voltage
as
Mode
with
M330461-01 Rev A
SCPI
N
N
N
N
N
N
N
N
N
C
C
C
C
C
N
N
N
N
N