Remote Programming By Voltage; Figure 8-6 Remote Current Programming Using 0-5 Vdc Or 0-10 Vdc Source - Ametek ASTDC60D1C-E00 Programming Manual

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

Asterion DC Series Programming

Remote Programming BY VOLTAGE

8.3.2
Remote Analog reference source of the Output Voltage, Current and Power can be
selected as Voltage by sending the following SCPI Command:
SOUR:ANALOG:PROG:SOUR VOLT
8.3.2.1 R
C
EMOTE
URRENT
Analog Reference source is selected as Voltage and programming mode of output
Current as external by sending following SCPI command.
SOUR:ANALOG:PROG:SOUR VOLT
SOUR:CURR:PROG EXT
The DC voltage source is connected between Pin 19 (IPRG_VSOUR) and the return Pin
18 (RTN_PRG), refer to Figure 8-6. Default FSC voltage value is 10V, where 10V
corresponds to 100% output current. The corresponding voltage-programming
coefficients for output current are (100% rated output current) / FSC VDC. This produces
transfer functions for output current, as follows:
Iout = Vdc * (100% rated output current) / 10 VDC), with Vdc in volts, or
Iout = Vdc * (100% rated output current) / FSC VDC), with Vdc in volts.
The Full-Scale voltage value can be modified to any voltage between 2V to 10V
from below SCPI command. For example, To set 5V as full scale for Current
programming send below command
SOUR:CURR:PROG:FSC 5

Figure 8-6 Remote Current Programming Using 0-5 VDC or 0-10 VDC Source

8.3.2.2 R
V
EMOTE
OLTAGE
Analog Reference source is selected as Voltage and programming mode of Output
M330461-01 Rev A
P
V
ROGRAMMING BY
OLTAGE
P
V
ROGRAMMING BY
OLTAGE
External User Control Signal Connector
S
OURCE
IPRG_VSOUR
19
18
S
OURCE
0-10VDC
VOLTAGE
Source
8-13