Figure 8-4 Remote Voltage Programming Using Resistance; Figure 8-5 Remote Power Programming Using Resistance - Ametek ASTDC60D1C-E00 Programming Manual

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

External User Control Signal Connector

Figure 8-4 Remote Voltage Programming Using Resistance

8.3.1.3 R
P
EMOTE
OWER
Analog Reference source is selected as Resistance and programming mode of output
Power as external by sending following SCPI command.
SOUR:ANALOG:PROG:SOUR CURR
SOUR:POW:PROG EXT
The
resistance-programming
(100% rated output power) / 5 kΩ, with input at Pin 34 (PPRG_ISOUR) and return to
Pin 18 (RTN_PRG). Refer to Figure 8-5. An internal current source, factory-set at 1
mA, from Pin 20 is utilized to drive the resistance. This produces a transfer function
for output power, as follows:
Pout = R * (100% rated output power) / 5 kΩ), with R in kohms.
Full Scale power programming resistance can be modified from default 5kOhms to any
other value, from 2 kOhm to 10 kOhm. For example, To set 10 kOhms as full scale for
Power programming send below command
SOUR:POW:PROG:FSCR 10
Then the transfer function for output power, as follows:
Pout = R * (100% rated output power) / FSC kΩ), with R in kohms.

Figure 8-5 Remote Power Programming Using Resistance

8-12
P
R
ROGRAMMING BY
ESISTANCE
default
Asterion DC Series Programming
coefficient
for
output
PPRG_ISOUR
34
18
M330461-01 Rev A
power
is
0-10k Ohm

Hide quick links: