Ametek ASTDC60D1C-E00 Programming Manual page 60

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

External User Control Signal Connector
9
DIO_IN1
10
REV_RY_EN
11
OUT_RY_EN
*
12
DIN_RTN
Remote ON/OFF /
13
ESTOP
Remote
14
*
ON/OFF_RTN
8-4
Voltage Rating: Maximum 24 V, Minimum -5V
Low state 0.3 V max, High State 2.7 V min.
User digital input, function to be assigned by user.
Signal connects to Open-anode of opto-isolator diode
with 1kΩ series resistor internal to power supply.
DIGITAL
Signal return: Pin 12, Circuit is electrically connected to
INPUT
the output power negative terminal
Voltage Rating: Maximum 24 V, Minimum -5V
Low state 0.3 V max, High State 2.7 V min.
User digital input, enables high output on pin 38.
Signal connects to Open-anode of opto-isolator diode
with 1kΩ series resistor internal to power supply.
DIGITAL
Signal return: Pin 12, Circuit is electrically connected to
INPUT
the output power negative terminal
Voltage Rating: Maximum 24 V, Minimum -5V
Low state 0.3 V max, High State 2.7 V min.
User digital input, enables high output on pin 37.
Signal connects to Open-anode of opto-isolator diode
with 1kΩ series resistor internal to power supply.
DIGITAL
Signal return: Pin 12, Circuit is electrically connected to
INPUT
the output power negative terminal
Voltage Rating: Maximum 24 V, Minimum -5V
Low state 0.3 V max, High State 2.7 V min.
Return/GND. Internally, pins 12, 14, 15,18, 22, 28, 29, 36,
RETURN FOR
40, and 41 are kept at the same DC potential. Circuit is
DIGITAL
electrically connected to the output power negative
INPUTS
terminal.
Control input for Output ON/OFF.
Switch/Relay contact closure or direct short-circuit from
this terminal to signal return will enable (turn-on) the
ON/OFF
output of the supply
control
Remote circuit must sink up to 3 mA from 5 VDC to
INPUT
enable.
Signal return: Pin 14, Circuit is electrically connected to
the output power negative terminal
RETURN FOR
Return/GND. Internally, pins 12, 14, 15, 18, 22, 28, 29,
REMOTE
36, 40, and 41 are kept at the same DC potential.
ON/OFF
Asterion DC Series Programming
M330461-01 Rev A

Hide quick links: