Series Programming
Asterion DC
•
Maskable fault interrupt
•
Hold and trigger
•
External relay control.
•
Full calibration
READBACK FUNCTIONS
2.7
The below functions are common to all communication interfaces (RS232, IEEE 488.2
GPIB and Ethernet).
•
Actual measured voltage and current
•
Voltage and current settings
•
User voltage and current limits
•
Overvoltage protection setting
•
Status and Accumulated Status registers
•
Programming error codes
•
Fault codes
•
Manufacturer, power supply model, and firmware version identification
SPECIFICATIONS
2.8
Specifications are subject to change without notice. Refer to your Asterion DC power
supply operation manual for effects of line regulation, load regulation, and temperature
on accuracy specifications. Specifications are common to all interfaces (RS232, IEEE
488.2 GPIB and Ethernet).
Programming Resolution
2.8.1
Voltage:
Current:
Overvoltage Protection: 0.1% of full scale (full scale is 110% of max output
Power Output:
Programming Accuracy
2.8.2
Voltage:
Current:
Overvoltage Protection: ± (1.0% of max output voltage)
Power Output: ± (0.3% of rated output power)
* After 30 minutes operation with fixed line, load, and temperature.
M330461-01 Rev A
0.012% of full scale
0.012% of full scale
voltage.)
0.012% of full scale
± (0.1% of maximum output voltage)
± (0.2% of maximum output current) *
Remote/Local Selection
2-3