Source Scpi Command Reference - Ametek ASTDC60D1C-E00 Programming Manual

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

Asterion DC Series Programming

SOURCE SCPI Command Reference

9.5.2
The letter "C" in the "SCPI" column means that the command syntax is SCPI compliant;
an "N" in the "SCPI" column means that the command syntax is not part of the SCPI
definition.
Command
SOURce:ANALOG:PROGram:SOURce <string>
SOURce:ANALOG:PROGram:SOURce?
SOURce:CURRent <NRf>
SOURce:CURRent?
SOURce:CURRent[:LEVel] <NRf>
SOURce:CURRent[:LEVel]?
SOURce:CURRent[:LEVel][:IMMediate] <NRf>
SOURce:CURRent[:LEVel][:IMMediate]?
SOURce:CURRent[:LEVel][:IMMediate]
[:AMPLitude] <NRf>
SOURce:CURRent[:LEVel][:IMMediate]
[:AMPLitude]?
SOURce:CURRent:MODE?
SOURce:CURRent:LIMit<NRf>
SOURce:CURRent:LIMit?
SOURce:CURRent:LIMit[:AMPLitude] <NRf>
SOURce:CURRent:LIMit[:AMPLitude]?
M330461-01 Rev A
External User Control Signal Connector
Description
Changes the source for EXTernal analog
programming Mode. Valid arguments are
VOLT, CURR and MA420.
VOLT – Voltage source (0-10V range)
CURR – Resistive load on constant 1mA
source (0-10kOhm). 1mA current source is in
built in power supply.
MA420 – Standard 4-20mA source
Returns the setting of External analog
programming source.
Sets the output current in amps (default) or in
milliamps.
Returns the output current in amps or in
milliamps
Sets the output current in amps (default) or in
milliamps.
Returns the output current in amps or in
milliamps.
Sets the output current in amps (default) or in
milliamps.
Returns the output current in amps or in
milliamps
Sets the output current in amps (default) or in
milliamps.
Returns the output current in amps or in
milliamps
Returns the mode of operation of the power
supply.
0 - Constant voltage operation,
1 - Constant current operation and
2 - constant power operation
Sets an upper soft limit on the programmed
output current for the supply. The soft limit
prevents the supply from being inadvertently
programmed above the soft limit, thus providing
a method for protecting the load against
damaging currents.
Returns the upper soft limit on the programmed
output current for the supply.
Sets an upper soft limit on the programmed
output current for the supply.
Returns the upper soft limit on the programmed
output current for the supply.
SCPI
N
N
C
C
C
C
C
C
C
C
N
C
C
C
C
9-15