Asterion DC Series Programming
MEASURE SCPI COMMAND SUBSYSTEM
9.6
This section first presents a tree summary of the MEASure commands and then
provides a tabular description.
MEASURE SCPI Command Summary
9.6.1
MEASure
:CURRent
:CURRent?
:AVErage <NR1>
:AVErage?
:PROGram?
:POWer?
:PROGram?
:VOLTage?8
:VOLTage
:AVErage <NR1>
:AVErage?
:PROGram?
:PROTection
MEASURE SCPI Command Reference
9.6.2
The letter "C" in the "SCPI" column means that the command syntax is SCPI compliant;
an "N" in the "SCPI" column means that the command syntax is not part of the SCPI
definition.
Command
MEASure:CURRent?
MEASure:CURRent
<NR1>
MEASure:CURRent
MEASure:CURRent
MEASure:POWer?
MEASure:PROGram?
MEASure:VOLTage?
MEASure:VOLTage:AVErage
<NR1>
M330461-01 Rev A
:PROGram?
Returns the floating point value of the DC output
current in amps.
Enter a value of 3 to 9 to set the number of readings to
:AVErage
average together when returning the current value from
the MEAS:CURR? command to reduce noise in the
readback readings. The value of 3 (factory default)
provides the fastest response time in the readings, but
less rejection of noise.
Returns the number 3 to 9 to indicate the number of
:AVErage?
readings to average together when taking a current
reading.
Returns the programmed output current from external
:PROGram?
Analog current programming feature.
Returns the floating point value of the measured output
power in watts.
Returns the programmed output power from external
Analog power programming feature.
Returns the floating point value of the DC output
voltage in volts.
Enter a value of 1 to 5 to set the number of readings to
average together when returning the voltage value from
the MEAS:VOLT? command. This function reduces
noise in the readback readings. The value of 1 (factory
External User Control Signal Connector
Description
SCP
I
C
N
N
C
N
9-21