Ametek ASTDC60D1C-E00 Programming Manual page 101

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

Asterion DC Series Programming
Command
SOURce:VOLTage:PROGram:FSCR?
SOURce:VOLTage:MONitor:FSC <NRf>
SOURce:VOLTage:MONitor:FSC?
SOURce:POWer <NRf>
SOURce:POWer?
SOURce:POWer:MAXimum?
SOURce:POWer:LIMit <NRf>
SOURce:POWer:LIMit?
SOUR:POWer:PROGram <string>
SOUR:POWer:PROGram?
SOUR:POWer:PROGram:FSC <NRf>
SOUR:POWer:PROGram:FSC?
SOUR:POWer:PROGram:FSCR <NRf>
SOUR:POWer:PROGram:FSCR?
SOUR:POWer:MONitor:FSC <NRf>
SOUR:POWer:MONitor:FSC?
SOURce:DIGINP:DIN1?
SOURce:DIGINP:DIN2?
M330461-01 Rev A
External User Control Signal Connector
Description
Current(Resistance) as programming source.
Valid Range is from 2 to 10kOhm.
Returns the Full-scale Resistance, at which Full
scale Voltage will be programmed.
Sets Full Scale voltage on voltage monitor
pin(VMON), when power supply is producing full
scale output voltage.
Returns the full scale voltage set for Voltage
monitor pin (VMON)
Sets the maximum power limit
Returns the set power.
Returns the Maximum power that can be
programmed with given hardware configuration
and Input voltage conditions.
Sets an upper soft limit on the programmed
output power for the supply. The soft limit
prevents the supply from being inadvertently
programmed above the soft limit, thus providing
a method for protecting the load against
damaging power.
Returns the upper soft limit on the programmed
output power for the supply.
Changes the Power programming mode of the
supply. Valid arguments are INT/0 (Internal
Digital Power programming)
EXT/1 (External analog Power programming)
ADD/2 (Add Internal and External Power
programming values)
Returns the setting of Power programming mode
Sets the Full-Scale voltage, at which Full Scale
Power will be programmed in external Power
Programming
Mode
programming source. Valid Range is from 2 to
10V.
Returns the Full-scale Voltage, at which Full
Scale Power will be programmed.
Sets the Full-Scale resistance, at which Full
Scale Power will be programmed in external
Power
Programming
Current(Resistance) as programming source.
Valid Range is from 2 to 10kOhm.
Returns the Full-scale Resistance, at which Full
Scale Power will be programmed.
Sets Full Scale voltage on power monitor pin
(PMON), when power supply is producing full
scale output power.
Returns the full scale voltage set for Power
monitor pin (PMON)
Returns the status of digital input 1 at the
Remote Analog Programming connector
Returns the status of digital input 2 at the
Remote Analog Programming connector
with
voltage
as
Mode
with
9-19
SCPI
N
C
C
N
N
N
N
N
N
N
N
N
N
N
N
N

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sorensen asterion dc seriesAstdc125d1c-e00

Table of Contents