Figure 6-4. Lan Screen (Settings) - Ametek ASTDC60D1C-E00 Programming Manual

Rs232, usb, ethernet and ieee 488.2
Table of Contents

Advertisement

Asterion DC Series Programming
6.4.1.2
DHCP
MODE SELECTION USING SERIAL INTERFACE
1. Connect using a computer serial communications program such as Tera Term and
establish communication as described in section 4.2.2.
2. Turn ON DHCP mode using the SCPI command, SYST:NET:DHCPMODE 1.
3. Turn ON AUTO-IP mode using the SCPI command, SYST:NET:AUTOIP 1.
4. Type SYST:NET:APPLY <enter> to apply the Network settings.
5. After configuring the settings, verify with the queries, SYST:NET:DHCPMODE?
and SYST:NET:AUTOIP?.
6.4.1.3
IP
ADDRESS IDENTIFICATION FOR
1. Start with the power supply in the power-off state.
2. Connect a RJ-45 network cable from the power supply to the network with the
DHCP server.
3. Power on the power supply and allow the power supply to perform its initialization.
4. Identify the IP address assigned to the power supply by accessing the DHCP
server, by any of four ways:
a. Asking your network administrator.
b. Discovering it with a VXI-11 compliant discover program.
NOTE: The power supply is VXI-11 compliant, so even without access to the
c. Using front panel and navigating to Home  Control Interface  LAN  LAN
Settings. Refer to Figure 6-4. LAN Screen (Settings).
d. Using a computer serial communications program such as Tera Term, set for
the same baud as Asterion DC power supply (Refer to Figure 6-5) no parity, 8
data bits, 1 stop bit. Use SCPI command SYST:NET:IP? <Enter> to get the IP
address.
To find RS232 Settings of the power supply, navigate to Home  Control
Interface  RS232  RS232 Settings.
M330461-01 Rev A
DHCP
DHCP server, it is still possible to discover the IP address assigned to
the power supply with programs such as National Instrument's NI-
VISA.

Figure 6-4. LAN Screen (Settings)

Ethernet Configuration and Remote Programming
MODE OF OPERATION
6-9