SCPI Status Implementation
Command
SOURce:CURRent:RAMP <NRf> <NRf>
SOURce:CURRent:RAMP?
SOURce:CURRent:RAMP:ABORt
SOURce:CURRent:RAMP:ALL?
SOURce:CURRent:RAMP:HTRIGgered <NRf>
<NRf>
SOURce:CURRent:RAMP:HTRIGgered?
SOURce:CURRent:RAMP:TRIGgered <NRf>
<NRf>
SOURce:CURRent:RAMP:TRIGgered?
SOURce:CURRent:TRIGgered <NRf>
SOURce:CURRent:TRIGgered?
SOURce:CURRent:TRIGgered[:AMPLitude] <NRf>
SOURce:CURRent:TRIGgered[:AMPLitude]?
SOURce:CURRent:TRIGgered:CLEar
SOURce:CURRent:PROGram <string>
SOURce:CURRent:PROGram?
SOURce:CURRent:PROGram:FSC <NRf>
SOURce:CURRent:PROGram:FSC?
SOURce:CURRent:PROGram:FSCR <NRf>
SOURce:CURRent:PROGram:FSCR?
9-16
Asterion DC Series Programming
Description
Sets the output current to ramp from the present
value to the specified value (first argument) in the
specified time (second argument).
Function description below.
Returns 1 if the ramp is in progress, and 0 if the
ramp is completed.
Aborts ramping and clears trigger mode.
Returns the ramping status.
Sets the value of the output current to ramp to be
implemented when the hardware trigger is
received.
Returns the value of the output current to ramp
to be implemented when the hardware trigger is
received.
Sets the output current to ramp from the present
value to the specified value (first argument) in
the specified time (second argument) upon the
trigger command. See Ramp description below.
Returns the value that the output current is to
ramp to (first value) and the time that it is to ramp
(second value) upon the trigger command.
Sets the output current to the values <NRf>
when TRIGger:TYPe 2 or 3 is sent
Returns the current level that will be set upon
receipt of the trigger.
Sets the output current to the values <NRf>
when TRIGger:TYPe 2 or 3 is sent
Returns the current level that will be set upon
receipt of the trigger.
Clears
the
value
SOURce:CURRent:TRIGger:AMPLitude
command.
Changes the Current programming mode of the
supply. Valid arguments are INT/0 (Internal
Digital Current programming)
EXT/1 (External analog Current programming)
ADD/2 (Add Internal and External Current
programming values)
Returns the setting of Current programming
mode
Sets the Full Scale voltage, at which Full scale
Current will be programmed in external Current
programming
Mode
programming source. Valid Range is from 2 to
10V.
Returns the Full-scale Voltage, at which Full
scale Current will be programmed.
Sets the Full Scale resistance, at which Full
scale Current will be programmed in external
Current
programming
Current(Resistance) as programming source.
Valid Range is from 2 to 10kOhm.
Returns the Full-scale Resistance, at which Full
scale Current will be programmed.
See Ramp
stored
by
the
with
voltage
as
Mode
with
M330461-01 Rev A
SCPI
N
N
N
N
N
N
C
C
C
C
C
C
C
N
N
N
N
N