AMREL SPS-A Series

REMOTE OUTPUT ON/OFF CONTROL

3.7
Remote output on/off control may be accomplished by contact closure or
by an isolated external AC/DC or TTL/CMOS voltage source.

3.7.1 REMOTE OUTPUT ON/OFF BY CONTACT CLOSURE

Output is on when contacts (J1-5 and J1-6) are closed. See Figure 3-15
for connection requirements.

Figure 3-15. Remote Output ON/OFFControl by Contact Closure

3.7.2 REMOTE OUTPUT ON/OFF CONTROL BY AN EXTERNAL 12 TO 240
VAC OR 6 TO 120 VDC OR TTL/CMOS SOURCE
Application of AC/DC or high state TTL/CMOS voltage will turn on the
power supply. See Figure 3-16 and Figure 3-17 for connection
requirements.

Figure 3-16. Remote Output ON/OFF Using Isolated AC or DC Voltage Source

M550129-01 Rev A
1
ON/OFF 5
6
ISO ON/OFF 1
+
ISO RTN 2
-
AC OR DC
SOURCE
14
25
14
25
Operation
3-23