3.5.2 EXTERNAL VOLTAGE PROGRAMMING USING A 0-5 OR
0-10 VDC VOLTAGE SOURCE
A DC voltage source for remote voltage programming is connected
between J1-9 (VP 5V) or J1-15 (VP 10V) and the return terminal J1-20
(VP RTN).
Note: The return terminal (VP RTN) must be referenced directly to or
within ±3V of the power supply common, J1-24.
The voltage coefficient for 5V remote voltage programming is 5 volts =
100% of rated output voltage.
The voltage coefficient for 10V remote voltage programming is 10 volts =
100% of rated output voltage. See Figure 3-12 for connection
requirements.
0-5 VDC
VOLTAGE
SOURCE

Figure 3-12. Remote Voltage Programming Using 0-5 or 0-10 VDC Voltage Source

3-20
1
COM 6
VP 5V 9
+
13
-
15 VP 10V
20 VP RTN
+
-