Setup Relating to Input/Output Signals (INPUT/OUTPUT Menu)
14-32
Chapter 14 Setup
• F-PVW (full-key preview)
F-PVW can be selected only when the keyer configuration is set to
CASCAD.
The F-PVW output consists of the preview output of the preceding
downstream keyer in which the keys of the preceding and current
downstream keyers have been inserted. For DSK4, therefore, you can
obtain F-PVW output with four keys inserted.
• Auto clean function: In a 3.5-M/E system, by connecting the CLEAN
output of the DVS-7000A to BKGD4 on the DMK-7000, signals
corresponding as shown below to the signals selected on the PGM and
PST buses are output from the CLEAN OUT connectors of the DMK-
7000.
Signals selected on the
PGM bus
M/E-1, M/E-2, M/E-3
Other than M/E-1, M/E-2,
M/E-3
Other than M/E-1, M/E-2,
M/E-3
In a 3-M/E system, if M/E-1 and M/E-2 are selected on the A bus of the
M/E specified as the last (for example M/E-3), then the respective M/E
clean signals are output from the CLEAN OUT connectors of the DVS-
7000A. If signals other than M/E-1 and M/E-2 are selected on the A bus
of M/E-3, then the M/E-3 clean signals are output from the CLEAN OUT
connectors of the DVS-7000A.
When the auto clean function is enabled ("ENBL"), the settings of F1,
F3, and F5 are ignored in relation to the output signals from the CLEAN
OUT connectors of the DVS-7000A and DMK-7000. Furthermore, the
auto preview function enabled with F4 (AUTO PVW) does not operate.
Signals selected on the
PST bus
Any signal
M/E-1, M/E-2, M/E-3
Other than M/E-1, M/E-2,
M/E-3
Signals output from the
CLEAN OUT connectors
of the DMK-7000
M/E-1, M/E-2, M/E-3
CLEAN signals
Signals selected on the
PGM bus
PGM/PST CLEAN signals