6. Fuel Gauge
A: REMOVAL
Disassemble the combination meter, and then re-
move the water temperature gauge and fuel gauge
assembly. <Ref. to IDI-16, DISASSEMBLY, Com-
bination Meter Assembly.>
B: INSTALLATION
Install in the reverse order of removal.
C: INSPECTION
Measure the fuel gauge resistance.
Terminal
Terminals IGN and GND
Terminals IGN and UNIT
Terminals UNIT and GND
If NG, replace the water temperature gauge and
fuel gauge assembly.
If OK, replace the combination meter printed circuit.
FUEL GAUGE
B6M1233A
Resistance
170±10 Ω
35±10 Ω
136±10 Ω
IDI-19