Avaya Definity SI Maintenance Manual page 2087

Table of Contents

Advertisement

PKT-INT (Packet Interface)
p. Error 2561 is an Active-Standby Peer Link test failure indicating a possible
failure of a Packet Interface on the active SPE or a failure of the
corresponding Packet Interface on the standby SPE. If the number of
errors exceeds a defined threshold, a MINOR alarm is raised. For more
information, refer to the repair procedures of Test #888.
q. Error 2817 indicates a Standby Packet Interface Translation RAM failure. A
MINOR alarm is raised when there are 1 to 5 bad memory locations.
Execute the test packet-interface command and follow repair procedures
described for Test #887.
r. Errors 3074, 3073, and 3072 indicate Packet Interface Transmit Buffer
Overflow, which means that the number of transmit buffers required by
software exceeded the number available. A 3074 error is generated when
the Packet Interface sends an in-line hardware error to maintenance
software indicating transmit buffer overflow. As part of the background
recovery action for this error, maintenance software automatically runs the
Maintenance Looparound Test (#886). If that test fails, maintenance
software generates Error Types 3073 and 3072, and it requests a system
WARM restart. If, after the WARM restart, transmit buffer overflow errors
continue to be reported, maintenance software generates Error Type 100
and resets the Packet Interface. High or Critical Reliability systems request
a SPE interchange instead of a Packet Interface reset, if the health of the
standby SPE allows an interchange.These errors may be the result of
system overload due to a problem with communication between the Packet
Interface and the EPNs.
1. Clear errors against any of these components first:
2. Enter the test packet-interface short command against the Packet
3. If the test fails, repeat the test 5 times.
4. If it continues to fail, follow normal escalation procedures.
555-233-123
the Expansion Interface circuit pack
C-LAN circuit pack
BRI Line circuit pack and BRI endpoints
BRI Trunk circuit pack
the Universal DS1 circuit pack supporting PRI service
Media Processor circuit pack
MAPD circuit pack
LAN Gateway circuit pack (TN566, TN2208)
Interface associated with the error. If the Maintenance Looparound
Test (#886) passes, the alarm clears.