Digital Operator Display
Cause
The option card installed into port CN5-A is
incompatible with the drive
A PG option card is connected to option port
CN5-A
Digital Operator Display
Cause
The option board connection to port CN5-A is
faulty
Digital Operator Display
to
oFA03 to oFA06
oFA10, oFA11
,
oFA12 to oFA17
to
oFA30 to oFA43
to
Cause
Option card or hardware is damaged
Digital Operator Display
Cause
The option card installed into port CN5-B is
incompatible with the drive
A communication option card has been
installed in option port CN5-B
Digital Operator Display
Cause
The option board connection to port CN5-B is
faulty
Digital Operator Display
Cause
An option card of the same type is already
installed in option port CN5-A
An input option card is already installed in
option port CN5-A
Digital Operator Display
to
oFb03 to oFb11
to
oFb12 to oFb17
oFb30 to oFb43
to
Cause
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
Option Card Connection Error at Option Port CN5-A
oFA00
Option compatibility error
Check if the drive supports the option card to be installed. Contact Yaskawa for assistance.
PG option boards are supported by option ports CN5-B and CN5-C only. Place the PG option card into
the correct option port.
Option Card Fault at Option Port CN5-A
oFA01
Option not properly connected
• Turn the power off and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed properly.
• If the option is not a communication option card, try to use the card in another option port. If the option
card works properly in a different option port, replace the drive because port CN5-A is damaged. If the
error persists (oFb01 or oFC01 occur), replace the option board.
Option card error occurred at option port CN5-A
Replace the option card.
Option Card Fault at Option Port CN5-B
oFb00
Option compatibility error
Make sure the drive supports the option card to be installed. Contact Yaskawa for assistance.
Communication option cards are only supported by option port CN5-A. It is not possible to install more
than one comm. option.
Option Card Fault at Option Port CN5-B
oFb01
Option not properly connected
• Turn off the power and reconnect the option card.
• Check if the option card is properly plugged into the option port. Make sure the card is fixed properly.
• Try to use the card in another option port (in case of a PG option use port CN5-C). If the option cards
works in the other port, replace the drive because port CN5-B is damaged. If the error persists (oFA01
or oFC01 occur), replace the option board.
Option Card Fault at Option Port CN5-B
oFb02
Same type of option card already connected
Except for PG options, each option card type can only be installed once. Make sure only one type of option
card is connected.
Install a comm. option, a digital input option, or an analog input option . The same type of card cannot
be installed twice.
Option card error occurred at Option Port CN5-B
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
6.4 Fault Detection
6
307

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents