No.
(Addr.
Name
Hex)
C5-28
Motor 2 ASR Integral Limit
(35D)
C5-32
Integral Operation during
(361)
Accel/Decel for Motor 2
C5-37
Motor 2 Inertia
(278)
C5-38
Motor 2 Load Inertia Ratio
(279)
<1> Default setting is determined by parameter A1-02, Control Mode Setting.
<2> The setting range is 1.00 to 300.00 in CLV and AOLV/PM control modes.
<3> Default setting is dependent on parameter E5-01, Motor Code Selection.
<4> Default setting is dependent on parameters C6-01, Drive Duty Selection, and o2-04, Drive Model Selection.
<5> Default setting is determined by the control mode for motor 2 (E3-01).
u

C6: Carrier Frequency

No.
(Addr.
Name
Hex)
C6-01
Drive Duty Selection
(223)
C6-02
Carrier Frequency Selection
(224)
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
Description
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
Sets the ASR integral upper limit for motor 2 as a percentage of maximum
output frequency (E3-04).
V/f
V/f w PG
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
0: Disabled. Integral functions for motor 2 are enabled only during constant
speed.
1: Enabled. Integral functions are always enabled for motor 2, during accel/
decel and during constant speed.
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
Sets the inertia of motor 2 alone without the load. This value is automatically
set during ASR or Inertia Auto-Tuning.
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
Sets the ratio between the motor 2 and machine inertia. This value is
automatically set during ASR or Inertia Auto-Tuning.
Description
All Modes
0: Heavy Duty (HD) for constant torque applications.
1: Normal Duty (ND) for variable torque applications.
All Modes
1: 2.0 kHz
2: 5.0 kHz
3: 8.0 kHz
4: 10.0 kHz
5: 12.5 kHz
6: 15.0 kHz
7: Swing PWM1 (Audible sound 1)
8: Swing PWM2 (Audible sound 2)
9: Swing PWM3 (Audible sound 3)
A: Swing PWM4 (Audible sound 4)
B to E: No setting possible
F: User-defined (determined by C6-03 through C6-05)
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
B.5 C: Tuning
Values
Page
Default: 400%
Min.: 0
165
Max.: 400
Default: 0
165
Range: 0, 1
<4>
Default:
2
166
Min.: 0.0001 kgm
2
Max.: 600.00 kgm
Default: 1.0
Min.: 0.0
166
Max.: 6000.0
Values
Page
Default: 1
166
Range: 0, 1
<1>
Default:
167
Range: 1 to 9;
A, F
395
B

Hide quick links: