H2-oo
Function
Setting
30
During torque limit
31
During speed limit
During speed limit in Torque
32
Control
33
Zero Servo complete
37
During frequency output
38
Drive enabled
39
Watt hour pulse output
3C
LOCAL/REMOTE status
3D
During speed search
3E
PID feedback low
3F
PID feedback high
4A
During KEB Ride-Thru
4B
During short circuit braking
4C
During fast stop
4D
oH Pre-alarm time limit
4E
Braking transistor fault (rr)
4F
Braking resistor overheat (oH)
60
Internal cooling fan alarm
Rotor position detection
61
complete
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
H2 Multi-Function Digital Output Settings
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Closed: When the torque limit has been reached.
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
Closed: Speed limit has been reached.
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
Closed: Speed limit has been reached while using Torque Control.
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
Closed: Zero Servo operation has finished.
All Modes
Open: Either the drive has stopped or baseblock, DC Injection Braking, or Initial Excitation is
being performed.
Closed: Drive is running the motor (not in a baseblock state and DC Injection is not being
performed).
All Modes
Closed: Multi-function input set for "Drive enable" is closed (H1-oo = 6A).
All Modes
Output units are determined by H2-06. Outputs a pulse every 200 ms to indicate the kWh count.
All Modes
Open: REMOTE
Closed: LOCAL
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
Closed: Speed Search is being executed.
All Modes
Closed: PID feedback level is too low.
All Modes
Closed: The PID feedback level is too high.
All Modes
Closed: KEB Ride-Thru is being performed.
V/f
V/f w PG
OLV
OLV/PM
AOLV/PM
CLV/PM
Closed: Short Circuit Braking is active.
All Modes
Closed: A Fast Stop command has been entered from the operator or input terminals.
All Modes
Closed: oH pre-alarm time limit has passed.
All Modes
Closed: The built-in dynamic braking transistor failed.
All Modes
Closed: The dynamic braking resistor has overheated.
All Modes
Closed: Internal cooling fan alarm
V/f
V/f
V/f w PG
V/f w PG
OLV
OLV
OLV/PM
OLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
AOLV/PM
CLV/PM
CLV/PM
CLV/PM
CLV/PM
Closed: Drive has successfully detected the rotor position of the PM motor.
B.9 H Parameters: Multi-Function Terminals
Description
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
CLV
Page
225
226
226
226
226
226
226
226
227
227
227
227
227
227
227
227
227
227
B
227
421

Hide quick links: